UXBRIDGE, MA —
OSHA Inspection: FEATURE MARBLE & GRANITE, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FEATURE MARBLE & GRANITE, INC in 79 RIVER RD, UXBRIDGE, MA 01569 (NAICS 327991). OSHA activity number 344282470.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FEATURE MARBLE & GRANITE, INC
- Site address
- 79 RIVER RD
- City
- UXBRIDGE
- State
- MA
- ZIP
- 01569
- Mailing
- 79 RIVER RD, UXBRIDGE, MA 01569
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 5
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.178 A05
- Issued
- Oct 28, 2019
- Abate by
- Dec 16, 2019
- Penalty
- Initial $3,978 · Current $2,078 Reduced
General-duty citation text
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: 79 River Rd, Uxbridge, MA: On September 26, 2019 and at times prior, the company president operated a powered industrial truck that had a Titan FMJ3 crane attachment that was not listed on the data plate. The PIT was regularly used to lift and move heavy sheets of marble and granite. The PIT attachment reduced the lifting capacity and moved the load center far outside those listed on the data plate.
Recent events (2)
- — I (S) $2078
- — Z (S) $3978
1910.178 L02 II
- Issued
- Oct 28, 2019
- Abate by
- Dec 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. 79 River Rd, Uxbridge, MA: On September 4, 2019 and at times prior, the company president operated a powered industrial truck without having received appropriate training and triennial performance evaluation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 M05 I
- Issued
- Oct 28, 2019
- Abate by
- Dec 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(m)(5)(i): When a powered industrial truck is left unattended, load engaging means were not fully lowered, controls were not neutralized, power was not shut off, and brakes set. 79 River Rd, Uxbridge, MA: On September 26, 2019 and at times prior, employees were exposed to crushed by hazards due to a powered industrial truck that was left unattended with brakes not set and load engaging means not fully lowered.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 P01
- Issued
- Oct 28, 2019
- Abate by
- Dec 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition: 79 River Rd, Uxbridge, MA: On September 26, 2019 and at times prior, employees were exposed to struck by and crushed by hazards from a powered industrial truck that was being operated with an inoperative emergency brake.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G02 I
- Issued
- Oct 28, 2019
- Penalty
- Initial $3,978 · Current $2,078 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): 79 River Rd, Uxbridge, MA: On September 4, 2019 and at times prior, three circuit breakers had been removed from an active overcurrent protection panel and the live components inside were not guarded to protect employees who reached above the live parts to turn on and off the building lighting each day.
Recent events (2)
- — I (S) $2078
- — Z (S) $3978
1910.304 F01 IV
- Issued
- Oct 28, 2019
- Penalty
- Initial $0 · Current $0
8870
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel: 79 River Rd, Uxbridge, MA: On September 4, 2019 and at times prior, employees were exposed to electrical hazards from two adjacent overcurrent protection panels that were not accessible due to items being stored in front of them blocking emergency access.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 G05
- Issued
- Oct 28, 2019
- Penalty
- Initial $2,842 · Current $1,244 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: 79 River Rd, Uxbridge, MA: On September 4, 2019 and at times prior, employees were exposed to electrical hazards on a daily basis when plugging in and unplugging the water recirculating pump extension cord that had a missing grounding conductor pin.
Recent events (2)
- — I (S) $1244
- — Z (S) $2842
1910.305 G01 IV A
- Issued
- Oct 28, 2019
- Abate by
- Dec 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: 79 River Rd, Uxbridge, MA: On September 26, 2019 and at times prior, employees were exposed to burn and shock hazards on daily basis when plugging in and unplugging an extension cord that was permanently in place to energize the water recirculating pump.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K06
- Issued
- Oct 28, 2019
- Abate by
- Dec 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: 79 River Rd, Uxbridge, MA: On September 26, 2019 and at times prior, employees who voluntarily wore filtering facepiece device respirators provided by the employer had not been provided the Appendix D advisory information.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Feature Marble & Granite, INC
View Feature Marble & Granite, INC's full OSHA safety record →
More inspections in this industry (NAICS 327991)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344282470.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.