Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CAPITOL CEMENT CO., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CAPITOL CEMENT CO., INC. in 1645 W. FARRAGUT AVE., CHICAGO, IL 60640 (NAICS 237310). OSHA activity number 344287875.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Capitol Cement CO., INC. — free Get an email when a new federal OSHA severe-injury report for Capitol Cement CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
1645 W. FARRAGUT AVE.
City
CHICAGO
State
IL
ZIP
60640
Mailing
6231 N. PULASKI ROAD, CHICAGO, IL 60646
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
Employees
10
Ownership type
A

3 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 8, 2019
Abate by
Oct 15, 2019
Penalty
Initial $5,636 · Current $3,500 Reduced
29 CFR 1926.404(b)(1)(ii): All 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which were used by employees did not have approved ground-fault circuit interrupters for personnel protection:    a) On September 5, 2019, employees were provided with electrical tools and equipment connected by cord and plug to a Honeywell 7000 watt portable generator without the use of ground fault circuit interrupters.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5636

1926.651 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 8, 2019
Abate by
Oct 15, 2019
Penalty
Initial $4,508 · Current $3,000 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:    a) On September 5, 2019, an employee was not provided with a safe means of egress when working in a trench approximately 9 feet in depth, thereby exposing the employee to slip, trip, fall, cave-in and struck-by hazards.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4508

1926.652 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 8, 2019
Abate by
Oct 15, 2019
Penalty
Initial $4,508 · Current $0 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:    a) On September 5, 2019, employees were not adequately protected from the hazard of cave-ins while working in a trench that measured approximately 9 feet in depth.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4508

View Capitol Cement CO., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344287875.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.