LEETSDALE, PA —
OSHA Inspection: HUSSEY COPPER
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HUSSEY COPPER in 100 WASHINGTON AVENUE, LEETSDALE, PA 15056 (NAICS 331421). OSHA activity number 344290564.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HUSSEY COPPER
- Site address
- 100 WASHINGTON AVENUE
- City
- LEETSDALE
- State
- PA
- ZIP
- 15056
- Mailing
- 100 WASHINGTON AVENUE, LEETSDALE, PA 15056
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331421
- Employees
- 285
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Feb 6, 2020
- Abate by
- Mar 4, 2020
- Penalty
- Initial $13,494 · Current $8,780 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to severe burn, traumatic injuries, and/or death due to the reaction of water/steam coming in contact with molten metal: (a) Facility, Casting Department: On or about September 7, 2019, four employees were exposed to severe burns due to the reaction of water/steam and molten metal when the hose fittings installed on the Continental ARC16SC-12 hose, were not installed properly. It was found that the fittings on the hose were not in accordance to manufacturer's specifications. The manufacturer recommended crimp on the hose is 2.72 and this fitting was measured at 1.35. On September 7, 2019, the ARC15SC-12 hose failed under pressure at the coupling and caused the hydraulic ram to drop thus allowing molten coper to come in contact with the water/steam mixture resulting in a violent molten metal explosion.
Recent events (2)
- — I (S) $8780
- — Z (S) $13494
More inspections at Hussey Copper