Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALABAMA FIRE SPRINKLER CONTRACTORS, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of ALABAMA FIRE SPRINKLER CONTRACTORS, LLC in 1731 MONTGOMERY HWY, BIRMINGHAM, AL 35244 (NAICS 238220). OSHA activity number 344292339.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Alabama Fire Sprinkler Contractors, LLC — free Get an email when a new federal OSHA severe-injury report for Alabama Fire Sprinkler Contractors, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1731 MONTGOMERY HWY
City
BIRMINGHAM
State
AL
ZIP
35244
Mailing
PO BOX 1809, ALABASTER, AL 35007
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
15
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 4, 2019
Penalty
Initial $3,410 · Current $2,046 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:  (a)  On or about 9/06/19 - 1731 Montgomery Highway, Hoover, Al, an employee was operating a Rigid Power Drive without eye protection.
Recent events (2)
  • — I (S) $2046
  • — Z (S) $3410

1926.403 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 4, 2019
Penalty
Initial $3,410 · Current $2,046 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  (a)  On or about 9/06/19 - 1731 Montgomery Highway, Hoover, AL, an employee was operating a Rigid Power Drive that was plugged into a receptacle housed in a metal box that was not mounted.
Recent events (2)
  • — I (S) $2046
  • — Z (S) $3410

1926.404 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 4, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection:  (a)  On or about 9/06/19 - 1731 Montgomery Highway, Hoover, AL, an employee was operating a Rigid Power Drive that was plugged into a receptacle that did not have a GFCI.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 A02 II I

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 4, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(I): Protection was not provided to avoid damage to flexible cords and cables used for temporary wiring which passed through doorways or other pinch points:  (a)  On or about 9/06/19 - 1731 Montgomery Highway, Hoover, AL, an employee was operating a Rigid Power Drive that was plugged into a extension cord that was wedged under a metal door and connected to a receptacle inside of the building.