HOUSTON, TX ·
OSHA Inspection: TERCEL OILFIELD PRODUCTS USA L.L.C
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TERCEL OILFIELD PRODUCTS USA L.L.C in 11010 LUCERNE ST, HOUSTON, TX 77016 (NAICS 332710). OSHA activity number 344292735.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TERCEL OILFIELD PRODUCTS USA L.L.C
- Site address
- 11010 LUCERNE ST
- City
- HOUSTON
- State
- TX
- ZIP
- 77016
- Mailing
- 11010 LUCERNE ST
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 181
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.28 B01 I
- Issued
- Oct 22, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $13,260 · Current $7,956 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: On or about September 3, 2019, in building 11, above the Mandrel Cell Tube office, where an employee was exposed to a fall hazard while working on a walking-working surface with an unprotected side or edge that was 4 feet or more above a lower level.
Recent events (2)
- · I (S) $7956
- · Z (S) $13260
1910.212 A01
- Issued
- Oct 22, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $13,260 · Current $7,956 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about September 3, 2019: a. In building 10, north wall, where an employee was exposed to caught-by hazards while operating a Mori Seiki brand, CNC lathe, company ID S327, without interlocks to guard the rotating chuck. b. In building 10, west end center of the shop, where an employee was exposed to caught-by hazards while operating a Sharp brand, 1660L manual lathe, company ID C119, without a guard to cover the rotating chuck. c. In building 10, southwest corner of the shop, where an employee was exposed to caught-by hazards while operating an Ooya brand, RE-2M vertical mill, company ID M409, without a guard to cover the rotating chuck. d. In building 10, southeast area of the shop, where an employee was exposed to caught-by hazards while operating an Ooya brand, RE-1M vertical mill, company ID S402, without a guard to cover the rotating chuck. e. In building 11, north wall of the shop, where an employee was exposed to a caught-by hazards while operating a Rockford Machine Tool Co. brand 28 inch Hydraulic shaper, company ID T903, without a guard to cover the transversing part. f. In building 11, north wall of the shop, where an employee was exposed to a caught-by hazards while operating a Rockford Machine Tool Co. brand 28 inch Hydraulic shaper, company ID T904, without a guard to cover the transversing part. g. In building 11, north wall of the shop, where an employee was exposed to a caught-by hazards while operating a Rockford Machine Tool Co. brand 24 inch Hydraulic shaper, company unknown, without a guard to cover the transversing part. h. In building 11, west end center of the shop, where an employee was exposed to caught-by hazards while operating an Axelson Manufacture Co, manual lathe, company ID T123, without a guard to cover the rotating parts. i. In building 11, west end center of the shop, where employees were exposed to caught-by hazards while operating an Axelson Manufacture Co, manual lathe, company ID T123, without a guard to cover the rotating part on the headstock. j. In the weld shop, where an employee was exposed to a caught-by hazards while operating a Rockford Machine Tool Co. brand 28 inch Hydraulic shaper, company ID W906, without a guard to cover the transversing part.
Recent events (2)
- · I (S) $7956
- · Z (S) $13260
1910.212 A03 II
- Issued
- Oct 22, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $13,260 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s): On or about September 3, 2019: a. In building 10, on the north wall where an employee was exposed to caught-by and struck-by hazards while using a Marvel brand vertical saw, company ID G613, without a point of operation guard covering the unused portion of the blade. b. In building 10, west center area of the shop, where an employee was exposed to caught-by and struck-by hazards while using a Bridgeport brand vertical mill, company ID R222, without a point of operation guard. c. In building 10, west center area of the shop, where an employee was exposed to caught-by and struck-by hazards while using a Bridgeport brand vertical mill, company ID R223, without a point of operation guard. d. In building 10, north wall west end area of the shop, where an employee was exposed to caught-by and struck-by hazards while using a Bridgeport brand vertical mill, company ID G224, without a point of operation guard. e. In the weld shop, northwest corner of the shop, where an employee was exposed to caught-by and struck-by hazards while using a Johnford brand drill vertical mill (model 4AV3, serial number 7Y30CR) without a point of operation guard. f. In the weld shop, west wall center area of the shop, where an employee was exposed to caught-by and struck-by hazards while using a Fosdick brand drill (no serial number) without a point of operation guard.
Recent events (2)
- · I (S) $0
- · Z (S) $13260
1910.213 P04
- Issued
- Oct 22, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $13,260 · Current $7,956 Reduced
General-duty citation text
29 CFR 1910.213(p)(4): Belt sanding machinery was not provided with a guard at each nip point where the sanding belt ran onto a pulley, to prevent the operator's hands or fingers from coming into contact with nip points. On or about September 3, 2019, in the weld shop, west wall south end of the shop, where an employee was exposed to caught-by and struck-by hazards while using a horizontal sanding machine (unknown brand and serial number) without a guard covering the nip points.
Recent events (2)
- · I (S) $7956
- · Z (S) $13260
1910.242 B
- Issued
- Oct 22, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about September 3, 2019, in building 10, north wall at the Mori Seiki CNC lathe #S327, where an employee was exposed to struck-by injection hazards while cleaning equipment without reducing the air pressure below 30 p.s.i.. The air pressure measured at 100 p.s.i.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.303 F02
- Issued
- Oct 22, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: On or about September 9. 2019, in building 10, on the north wall, west end of the building where two breaker boxes containing several feeders and branch circuits were being used to provide power throughout the facility without having all of the disconnecting means or overcurrent devices labeled for its purpose or arranged so that the purpose was evident.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 332710)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344292735.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.