DORAVILLE, GA —
OSHA Inspection: SUPPLY NETWORK, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SUPPLY NETWORK, INC. in 100 PIEDMONT COURT SUITE A, DORAVILLE, GA 30340 (NAICS 332996). OSHA activity number 344297395.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SUPPLY NETWORK, INC.
- Site address
- 100 PIEDMONT COURT SUITE A
- City
- DORAVILLE
- State
- GA
- ZIP
- 30340
- Mailing
- 100 PIEDMONT COURT SUITE A, DORAVILLE, GA 30340
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332996
- Employees
- 45
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.252 B02 III
- Issued
- Oct 22, 2019
- Penalty
- Initial $3,261 · Current $1,957 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields:(a)(LOCATION)(IDENTIFY SPECIFIC OPERATIONS AND/OR CONDITIONS) Supply Network, Inc. dba Viking Fabrication Services, Doraville, GA - At the first welding station area of In the fabrication shop, employees were exposed to eyes flash burns from the two large openings on the welding screen near the saws, on or about 9/10/19.
Recent events (2)
- — I (S) $1956.6
- — Z (S) $3261
1910.134 C02 II
- Issued
- Oct 22, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: Supply Network, Inc. dba Viking Fabrication Services, Doraville, GA - In the Fabrication Shop, an employee was allowed to wear a half mask, negative pressure respirator. A medical evaluation had not been performed to determine if the employee was physically able to wear the respirator, on or about 9/10/19.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Supply Network, INC.
View Supply Network, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332996)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344297395.