WARWICK, RI —
OSHA Inspection: CNA PLASTERING, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of CNA PLASTERING, INC. in 3595 POST RD., WARWICK, RI 02886 (NAICS 238310). OSHA activity number 344297460.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CNA PLASTERING, INC.
- Site address
- 3595 POST RD.
- City
- WARWICK
- State
- RI
- ZIP
- 02886
- Mailing
- 3 ABBOT RUN VALLEY RD., CUMBERLAND, RI 02864
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 15
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.403 B02
- Issued
- Oct 9, 2019
- Penalty
- Initial $3,789 · Current $2,652 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: (a) On the second floor stairway landing: On or about 8/23/2019, two portable power strips were plugged into each other to provide additional receptacles for the tools and equipment being used.
Recent events (2)
- — I (S) $2652.3
- — Z (S) $3789
1926.404 B01 II
- Issued
- Oct 9, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection: (a) At the front of the building: On or about 8/23/2019, the employer used a Generac GP6500 portable generator that was not equipped with ground fault circuit interrupters, creating a possible shock hazard to employees.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 G01 III C
- Issued
- Oct 9, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(1)(iii)(C): Flexible cords and cables were run through doorways, windows, or similar openings: (a) At the front of the building: On or about 8/23/2019, a flexible cord was plugged into the portable generator and passed through a second story window, and the window was closed down on the extension cord.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238310)
More inspections in RI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344297460.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.