POMPANO BEACH, FL —
OSHA Inspection: CB STRUCTURES, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CB STRUCTURES, INC. in 301 N. FEDERAL HIGHWAY, POMPANO BEACH, FL 33062 (NAICS 238130). OSHA activity number 344299524.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CB STRUCTURES, INC.
- Site address
- 301 N. FEDERAL HIGHWAY
- City
- POMPANO BEACH
- State
- FL
- ZIP
- 33062
- Mailing
- 2251 BLOUNT RD, POMPANO BEACH, FL 33069
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 150
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.1053 A02
- Issued
- Dec 27, 2019
- Penalty
- Initial $6,819 · Current $6,137 Reduced
General-duty citation text
1926.1053(a)(2) Ladder rungs, cleats, and steps shall be parallel, level, and uniformly spaced when the ladder is in position for use. On or about 5 September 2019, by the sidewalk, employees were accessing a working platform of a tubular welded scaffold approximately 12 feet high by climbing the outside rails and not utilizing a ladder, exposing the employees to a fall hazard.
Recent events (3)
- — J (O) $6137
- — C (S) $6819
- — Z (S) $6819
1926.503 C
- Issued
- Dec 27, 2019
- Penalty
- Initial $6,819 · Current $6,137 Reduced
General-duty citation text
1926.503(c) "Retraining." When the employer has reason to believe that any affected employee who has already been trained does not have the understanding and skill required by paragraph (a) of this section, the employer shall retrain each such employee. Circumstances where retraining is required include, but are not limited to, situations where: (1) Changes in the workplace render previous training obsolete; or (2) Changes in the types of fall protection systems or equipment to be used render previous training obsolete; or (3) Inadequacies in an affected employee's knowledge or use of fall protection systems or equipment indicate that the employee has not retained the requisite understanding or skill. On or about 5 September, 2019, by the sidewalk entrance, two employees were working on top of a concrete wall under construction, without the use of fall protection, thereby exposing the employees to a fall hazard of up to 12 feet from ground level.
Recent events (3)
- — J (O) $6137
- — C (S) $6819
- — Z (S) $6819
More inspections at CB Structures, INC.