Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: DAYTON WALLS & CEILINGS, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of DAYTON WALLS & CEILINGS, INC. in 4079 LYMAN DRIVE, HILLIARD, OH 43026 (NAICS 238310). OSHA activity number 344300850.

Watch Dayton Walls & Ceilings, INC. — free Get an email when a new federal OSHA severe-injury report for Dayton Walls & Ceilings, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4079 LYMAN DRIVE
City
HILLIARD
State
OH
ZIP
43026
Mailing
4328 WEBSTER STREET, DAYTON, OH 45414
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
10
Ownership type
A

3 citations on file for this inspection.

1926.502 I02

Serious Gravity 10 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $13260.00 · Current $8000.00 Reduced
1926.502(i) Covers. Covers for holes in floors, roofs, and other walking/working surfaces shall meet the following requirements:  29 CFR 1926.502(i)(2): All other covers shall be capable of supporting, without failure, at least twice the weight of employees, equipment, and materials that may be imposed on the cover at any one time.   a. On or about September 9, 2019, located on a temporary platform at the 4th floor elevator shaft, the employer did not ensure that employees were protected from falls through two floor holes on the left and right ends of the platform by ensuring that floor hole covers were capable of supporting, without failure, at least twice the weight of employees, thereby exposing employees to a fall hazard of approximately 40 feet.  b. On or about September 11, 2019, located on a temporary platform at the 4th floor elevator shaft, the employer did not ensure that employees were protected from falls through two floor holes on the left and right ends of the platform by ensuring that floor hole covers were capable of supporting, without failure, at least twice the weight of employees, thereby exposing employees to a fall hazard of approximately 40 feet.   On September 11, 2019, employees were working from a temporary platform located in an elevator shaft. The employee stepped onto an unsupported, unsecured and unmarked floor hole cover on the left end of the platform which caused the employee to fall approximately 40 feet resulting in death.
Recent events (3)
  • — F (S) $8000
  • — C (S) $13260
  • — Z (S) $13260

1926.502 I03

Deleted Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(i)(3): All covers shall be secured when installed so as to prevent accidental displacement by the wind, equipment, or employees.   a. On or about September 9, 2019, located on a temporary platform at the 4th floor elevator shaft, the employer did not ensure that employees were protected from falls through two floor holes on the left and right ends of the platform by ensuring that floor hole covers were secured to prevent accidental displacement, thereby exposing employees to a fall hazard of approximately 40 feet.  b. On or about September 11, 2019, located on a temporary platform at the 4th floor elevator shaft, the employer did not ensure that employees were protected from falls through two floor holes on the left and right ends of the platform by ensuring that floor hole covers were secured to prevent accidental displacement, thereby exposing employees to a fall hazard of approximately 40 feet.   On September 11, 2019, employees were working from a temporary platform located in an elevator shaft. The employee stepped onto an unsupported, unsecured and unmarked floor hole cover on the left end of the platform which caused the employee to fall approximately 40 feet resulting in death.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.502 I04

Deleted Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(i)(4): All covers shall be color coded or they shall be marked with the word "HOLE" or "COVER" to provide warning of the hazard.  a. On or about September 9, 2019, located on a temporary platform at the 4th floor elevator shaft, the employer did not ensure that employees were protected from falls through three floor holes on the left and right ends and center of the platform by ensuring that floor hole covers were color coded or marked with the word HOLE or COVER, thereby exposing employees to a fall hazard of approximately 40 feet.  b. On or about September 11, 2019, located on a temporary platform at the 4th floor elevator shaft, the employer did not ensure that employees were protected from falls through three floor holes on the left and right ends and center of the platform by ensuring that floor hole covers were color coded or marked with the word HOLE or COVER, thereby exposing employees to a fall hazard of approximately 40 feet.   On September 11, 2019, employees were working from a temporary platform located in an elevator shaft. The employee stepped onto an unsupported, unsecured and unmarked floor hole cover on the left end of the platform which caused the employee to fall approximately 40 feet resulting in death.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0