Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: K. C. PRINTING SERVICES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of K. C. PRINTING SERVICES, INC. in 22292 N. PEPPER RD., LAKE BARRINGTON, IL 60010 (NAICS 323111). OSHA activity number 344302815.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch K. C. Printing Services, INC. — free Get an email when a new federal OSHA severe-injury report for K. C. Printing Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
22292 N. PEPPER RD.
City
LAKE BARRINGTON
State
IL
ZIP
60010
Mailing
22292 N. PEPPER RD., LAKE BARRINGTON, IL 60010
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
20
Ownership type
A

1 citation on file for this inspection.

1910.147 D

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 14, 2020
Abate by
Feb 28, 2020
Penalty
Initial $5,304 · Current $3,700 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) was not done in sequence to achieve energy control by performing the following steps as required by 29 CFR 1910.147(d)(1)-(6):  1.      Turn off and shut down power to the machinery,  2.      Physically locate and operate energy-isolating devices in such a manner as to isolate the machine or equipment from the energy source(s),  3.      Affix lockout/tagout devices to each energy isolating device,  4.      Verify isolation and de-energization of machinery have been accomplished prior to starting the maintenance and/or servicing work:      a) Pressroom- On or about September 11, 2019, employees were exposed to machine hazards associated with moving parts while performing maintenance and servicing tasks on the printing presses, including replacing  rollers and cleaning ink off rollers. The employer did not implement energy control application steps as the machine was not shut down or turned off to clean or remove rollers or ensuring that the inch mode button is not held down during the roller cleaning process [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving dissipation machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • — I (S) $3700
  • — Z (S) $5304

View K. C. Printing Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344302815.