Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACCURUS AEROSPACE ATHENS, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ACCURUS AEROSPACE ATHENS, LLC in 180 TRANS TECH DR, ATHENS, GA 30601 (NAICS 332710). OSHA activity number 344303953.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Accurus Aerospace Athens, LLC — free Get an email when a new federal OSHA severe-injury report for Accurus Aerospace Athens, LLC is published. One employer, no account, unsubscribe in one click.
Site address
180 TRANS TECH DR
City
ATHENS
State
GA
ZIP
30601
Mailing
180 TRANS TECH DR, ATHENS, GA 30601
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
150
Ownership type
A

5 citations on file for this inspection.

1904.40 A

Other-than-serious 1 instance 150 exposed
Issued
Oct 3, 2019
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours.    On or about September 10, 2019 at 180 Trans Tech Drive, Athens, Georgia, the employer failed to provide copies of the injury and illness records to an authorized representative.  Records were requested on September 10, 2019 were not provided to the Compliance officer until September 26, 2019 via email.
Recent events (2)
  • — I (O) $0
  • — Z (S) $5000

1910.134 C02 I

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Oct 3, 2019
Abate by
Oct 30, 2019
Penalty
Initial $11,934 · Current $0 Reduced
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible.    On or about September 10, 2019 at 180 Trans Tech Drive, Athens, Georgia where the employer provided respirators to employees  grinding on aluminum parts, the employer did not provide the employees with the information contained in Appendix D to 29CFR 1910.134.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11934

1910.134 D01 III

Other-than-serious 1 instance 2 exposed
Issued
Oct 3, 2019
Abate by
Oct 23, 2019
Penalty
Initial $11,934 · Current $4,000 Reduced
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form.    On or about September 10, 2019 at 180 Trans Tech Drive, Athens, Georgia where employee's prepped and grind on aluminum part to remove burrs and slight imperfection, the employer did identify and evaluate the respiratory hazards in the workplace associated with aluminum dust created during the process.
Recent events (2)
  • — I (O) $4000
  • — Z (S) $11934

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Oct 3, 2019
Abate by
Oct 16, 2019
Penalty
Initial $11,934 · Current $6,000 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.    On or about September 10, 2019 at 180 Trans Tech Drive, Athens, Georgia employees working with the CNC machine were exposed to a caught by hazards from rotation parts when the key on the right side of the door to the interlock was missing.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $11934

1910.253 B04 III

Serious Gravity 10 1 instance 150 exposed
Issued
Oct 3, 2019
Penalty
Initial $11,934 · Current $6,000 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least.    On or about September 10, 2019 at 180 Trans Tech Drive, Athens, Georgia employees were exposed to a fire and explosion hazard when behind the SNK machine oxygen and acetylene were stored 12 feet apart.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $11934

View Accurus Aerospace Athens, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344303953.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.