ATHENS, GA —
OSHA Inspection: ACCURUS AEROSPACE ATHENS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ACCURUS AEROSPACE ATHENS, LLC in 180 TRANS TECH DR, ATHENS, GA 30601 (NAICS 332710). OSHA activity number 344303953.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ACCURUS AEROSPACE ATHENS, LLC
- Site address
- 180 TRANS TECH DR
- City
- ATHENS
- State
- GA
- ZIP
- 30601
- Mailing
- 180 TRANS TECH DR, ATHENS, GA 30601
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 150
- Ownership type
- A
Citations
5 citations on file for this inspection.
1904.40 A
- Issued
- Oct 3, 2019
- Penalty
- Initial $5,000 · Current $0 Reduced
General-duty citation text
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours. On or about September 10, 2019 at 180 Trans Tech Drive, Athens, Georgia, the employer failed to provide copies of the injury and illness records to an authorized representative. Records were requested on September 10, 2019 were not provided to the Compliance officer until September 26, 2019 via email.
Recent events (2)
- — I (O) $0
- — Z (S) $5000
1910.134 C02 I
- Issued
- Oct 3, 2019
- Abate by
- Oct 30, 2019
- Penalty
- Initial $11,934 · Current $0 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible. On or about September 10, 2019 at 180 Trans Tech Drive, Athens, Georgia where the employer provided respirators to employees grinding on aluminum parts, the employer did not provide the employees with the information contained in Appendix D to 29CFR 1910.134.
Recent events (2)
- — I (S) $0
- — Z (S) $11934
1910.134 D01 III
- Issued
- Oct 3, 2019
- Abate by
- Oct 23, 2019
- Penalty
- Initial $11,934 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form. On or about September 10, 2019 at 180 Trans Tech Drive, Athens, Georgia where employee's prepped and grind on aluminum part to remove burrs and slight imperfection, the employer did identify and evaluate the respiratory hazards in the workplace associated with aluminum dust created during the process.
Recent events (2)
- — I (O) $4000
- — Z (S) $11934
1910.212 A01
- Issued
- Oct 3, 2019
- Abate by
- Oct 16, 2019
- Penalty
- Initial $11,934 · Current $6,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. On or about September 10, 2019 at 180 Trans Tech Drive, Athens, Georgia employees working with the CNC machine were exposed to a caught by hazards from rotation parts when the key on the right side of the door to the interlock was missing.
Recent events (2)
- — I (S) $6000
- — Z (S) $11934
1910.253 B04 III
- Issued
- Oct 3, 2019
- Penalty
- Initial $11,934 · Current $6,000 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least. On or about September 10, 2019 at 180 Trans Tech Drive, Athens, Georgia employees were exposed to a fire and explosion hazard when behind the SNK machine oxygen and acetylene were stored 12 feet apart.
Recent events (2)
- — I (S) $6000
- — Z (S) $11934
More inspections at Accurus Aerospace Athens, LLC
View Accurus Aerospace Athens, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344303953.