Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DCI SIGNS & AWNINGS, INC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of DCI SIGNS & AWNINGS, INC in 110 RIVERSIDE AVENUE, NEWARK, NJ 07104 (NAICS 561790). OSHA activity number 344305958.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch DCI Signs & Awnings, INC — free Get an email when a new federal OSHA severe-injury report for DCI Signs & Awnings, INC is published. One employer, no account, unsubscribe in one click.
Site address
110 RIVERSIDE AVENUE
City
NEWARK
State
NJ
ZIP
07104
Mailing
110 RIVERSIDE AVE, NEWARK, NJ 07105
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561790
Employees
14
Ownership type
A

13 citations on file for this inspection.

1910.106 D04 I

Serious Gravity 5 1 instance 14 exposed
Issued
Jan 13, 2020
Abate by
Mar 3, 2020
Penalty
Initial $3,696 · Current $2,100 Reduced

Hazardous substances 2590

29 CFR 1910.106(d)(4)(i): Opening(s) from inside flammable and combustible storage room(s) into other rooms or buildings were not provided with noncombustible liquid tight raised seal or ramp at least 4 inches in height:  a) 110 Riverside Avenue, Newark, NJ, 07104.    The employer did not install a raised seal or ramp at least four inches high in the flammable paint storage room for employees exposed to flammable organic solvents, including but not limited to xylene, in order to ensure that paint spills do not spread to other areas.    Violation occurred on or about 9/13/2019.
Recent events (3)
  • — F (S) $2100
  • — C (S) $3696
  • — Z (S) $3696

1910.106 D04 IV

Serious Gravity 5 1 instance 14 exposed
Issued
Jan 13, 2020
Abate by
Mar 3, 2020
Penalty
Initial $0 · Current $0

Hazardous substances 2590

29 CFR 1910.106(d)(4)(iv): Every inside storage room was not provided with either a gravity or a mechanical exhaust ventilation system. Such system was not designed to provide for a complete change of air within the room at least six times per hour:  a) 110 Riverside Avenue, Newark, NJ, 07104.    The employer did not install a ventilation system with at least six air changes per hour in the flammable paint storage room for employees exposed to flammable organic solvents, including but not limited to xylene, in order to ensure that the vapors do not reach the lower explosive limit (LEL).    Violation occurred on or about 9/13/2019.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.107 B05 I

Serious Gravity 5 1 instance 14 exposed
Issued
Jan 13, 2020
Abate by
Mar 3, 2020
Penalty
Initial $3,696 · Current $2,100 Reduced

Hazardous substances 2590

29 CFR 1910.107(b)(5)(i): There were no visible gauges, audible alarms or pressure activated devices installed in paint spray booths to indicate or ensure that the required air speed was maintained:  a) 110 Riverside Avenue, Newark, NJ, 07104.    The employer did not install a manometer or similar device for employees using a paint spray booth exposed to organic solvents, including but not limited to xylene, in order to ensure required air velocity is maintained.    Violation occurred on or about 9/13/2019.
Recent events (3)
  • — F (S) $2100
  • — C (S) $3696
  • — Z (S) $3696

1910.107 B05 IV

Serious Gravity 5 1 instance 14 exposed
Issued
Jan 13, 2020
Abate by
Mar 3, 2020
Penalty
Initial $0 · Current $0

Hazardous substances 2590

29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:  a) 110 Riverside Avenue, Newark, NJ, 07104.    The employer did not install a sprinkler system downstream and upstream of the filters for employees using a paint spray booth exposed to flammable organic solvents, including but not limited to xylene, in order to ensure fire suppression.    Violation occurred on or about 9/13/2019.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.107 C06

Serious Gravity 5 1 instance 14 exposed
Issued
Jan 13, 2020
Abate by
Mar 3, 2020
Penalty
Initial $3,696 · Current $2,100 Reduced

Hazardous substances 2590

29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations:  a) 110 Riverside Avenue, Newark, NJ, 07104.    The employer did not ensure that only intrinsically safe wiring was inside paint booth for employees using a the booth exposed to organic solvents, including but not limited to xylene, in order to ensure there was not an ignition source.    Violation occurred on or about 9/13/2019.
Recent events (3)
  • — F (S) $2100
  • — C (S) $3696
  • — Z (S) $3696

1910.134 C01

Serious Gravity 5 1 instance 14 exposed
Issued
Jan 13, 2020
Abate by
Mar 3, 2020
Penalty
Initial $3,696 · Current $2,100 Reduced

Hazardous substances 2590

29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  a) 110 Riverside Avenue, Newark, NJ, 07104.  The employer failed to develop and implement a written respiratory protection program for employees exposed to xylene who are required to use 3M half-face respirators equipped with P-100/OV filters during paint booth and welding operations.           Violation occurred on or about 9/13/2019.
Recent events (3)
  • — F (S) $2100
  • — C (S) $3696
  • — Z (S) $3696

1910.134 E01

Serious Gravity 5 1 instance 14 exposed
Issued
Jan 13, 2020
Abate by
Mar 3, 2020
Penalty
Initial $0 · Current $0

Hazardous substances 2590

29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a) 110 Riverside Avenue, Newark, NJ, 07104.  The employer failed to provide a medical evaluation before respirator fit test or use for employees exposed to xylene who are required to use 3M half-face respirators equipped with P-100/OV filters during paint booth and welding operations.            Violation occurred on or about 9/13/2019.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 F02

Serious Gravity 5 1 instance 14 exposed
Issued
Jan 13, 2020
Abate by
Mar 3, 2020
Penalty
Initial $0 · Current $0

Hazardous substances 2590

29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator:  a) 110 Riverside Avenue, Newark, NJ, 07104.  The employer failed to ensure that the employees were fit-tested prior to required use of 3M half-face respirators equipped with P-100/OV filters during paint booth and welding operations.            Violation occurred on or about 9/13/2019.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 K

Serious Gravity 5 1 instance 14 exposed
Issued
Jan 13, 2020
Abate by
Mar 3, 2020
Penalty
Initial $0 · Current $0

Hazardous substances 2590

29 CFR 1910.134(k): The employer did not provide comprehensive, understandable training which did not occur annually and/or more often if necessary:  a) 110 Riverside Avenue, Newark, NJ, 07104.  The employer failed to ensure that the employees were trained prior to required use of 3M half-face respirators equipped with P-100/OV filters during paint booth and welding operations.           Violation occurred on or about 9/13/2019.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.304 B03 II C 3

Serious Gravity 5 2 instances 14 exposed
Issued
Jan 13, 2020
Abate by
Mar 3, 2020
Penalty
Initial $3,696 · Current $2,100 Reduced
29 CFR 1910.304(b)(3)(ii)(C)(3): Each cord set, attachment cap, plug, and receptacle of cord sets, and any equipment connected by cord and plug found damaged or defective was used before being repaired:  a) 110 Riverside Avenue, Newark, NJ, 07104.    The employer did not adequately repair damaged cords for employees using cord and plug electrical devices to include a hand held drill and drill press throughout the facility.    Violation occurred on or about 9/13/2019.
Recent events (3)
  • — F (S) $2100
  • — C (S) $3696
  • — Z (S) $3696

1910.1200 E01

Serious Gravity 5 1 instance 14 exposed
Issued
Jan 13, 2020
Abate by
Mar 3, 2020
Penalty
Initial $3,696 · Current $2,500 Reduced

Hazardous substances 2590

29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):   a) 110 Riverside Avenue, Newark, NJ, 07104.  The employer did not develop or implement a written hazard communication program for employees using chemicals including, but not limited to, welding fumes and organic paint solvent vapors.   Violation occurred on or about 9/13/2019.
Recent events (3)
  • — F (S) $2500
  • — C (S) $3696
  • — Z (S) $3696

1910.1200 E01 I

Serious Gravity 5 1 instance 14 exposed
Issued
Jan 13, 2020
Abate by
Mar 3, 2020
Penalty
Initial $0 · Current $0

Hazardous substances 2590

29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet:  a) 110 Riverside Avenue, Newark, NJ, 07104.  The employer did not develop a list of the hazardous chemicals for employees working with chemicals including, but not limited to, welding fumes and organic paint solvent vapors.   Violation occurred on or about 9/13/2019.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 14 exposed
Issued
Jan 13, 2020
Abate by
Mar 3, 2020
Penalty
Initial $0 · Current $0

Hazardous substances 2590

29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) 110 Riverside Avenue, Newark, NJ, 07104.  The employer did not provide initial hazard communication training for employees conducting erlding and spray painting exposed to chemicals including, but not limited to, welding fumes and organic paint solvent vapors.   Violation occurred on or about 9/13/2019.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View DCI Signs & Awnings, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344305958.