Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: G&G DISTRIBUTORS

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of G&G DISTRIBUTORS in 275 N MIDLAND AVE, SADDLE BROOK, NJ 07663 (NAICS 424930). OSHA activity number 344308028.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G&G Distributors — free Get an email when a new federal OSHA severe-injury report for G&G Distributors is published. One employer, no account, unsubscribe in one click.
Establishment
G&G DISTRIBUTORS
Site address
275 N MIDLAND AVE
City
SADDLE BROOK
State
NJ
ZIP
07663
Mailing
275 N MIDLAND AVE, SADDLE BROOK, NJ 07663
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424930
Employees
30
Ownership type
A

9 citations on file for this inspection.

1910.23 C11

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 20, 2019
Penalty
Initial $3,978 · Current $2,387 Reduced
29 CFR 1910.23(c)(11): Portable ladders used to gain access to an upper landing surface did not have side rails that extended at least 3 feet (0.9 m) above the upper landing surface     a) Warehouse: Employees stacking merchandise were exposed to fall hazards of approximately 7 feet while utilizing a ladder that extended less than one foot above the landing, on or about 8/18/19
Recent events (2)
  • — I (S) $2386.8
  • — Z (S) $3978

1910.28 B01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 20, 2019
Penalty
Initial $5,304 · Current $3,182 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems:  a) Warehouse - Dry Area: Employees were exposed to fall hazards of approximately 9 feet while staking merchandise by walking on a raised deck without any means of fall protection, on or about 8/19/19
Recent events (2)
  • — I (S) $3182.4
  • — Z (S) $5304

1910.37 B04

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 20, 2019
Abate by
Dec 10, 2019
Penalty
Initial $6,630 · Current $3,978 Reduced
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:  a) Warehouse: Employees were exposed to fire hazards while stacking merchandise inside a warehouse that only had directional signs on the floor, on or about 8/19/19.
Recent events (2)
  • — I (S) $3978
  • — Z (S) $6630

1910.110 E04 III

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 20, 2019
Penalty
Initial $3,978 · Current $2,387 Reduced
29 CFR 1910.110(e)(4)(iii): Permanent and removable fuel containers were not securely mounted to prevent jarring loose, slipping, or rotating:  a) Warehouse area: Propane tank being used to fuel PIT was not secured in place by the index pin, on or about 8/19/19.
Recent events (2)
  • — I (S) $2386.8
  • — Z (S) $3978

1910.110 F02 I

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 20, 2019
Penalty
Initial $3,978 · Current $2,387 Reduced
29 CFR 1910.110(f)(2)(i): Containers in storage were not located so as to minimize physical damage, or tampering from unauthorized persons:   a) Overhead Door: Compressed gas cylinder containing propane was unsecured and stored next to exit door, on or about 8/19/19.
Recent events (2)
  • — I (S) $2386.8
  • — Z (S) $3978

1910.178 L06

Serious Gravity 10 1 instance 4 exposed
Issued
Nov 20, 2019
Penalty
Initial $9,282 · Current $5,569 Reduced
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):    a) Warehouse area: Operators of a Propane PIT had not been certified by the employer as trained, on or about 6/16/19.  b) Warehouse area: Operators of Electric Aerial Work Platform had not been certified by the employer as trained, on or about 6/13/19.
Recent events (2)
  • — I (S) $5569.2
  • — Z (S) $9282

1910.303 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Nov 20, 2019
Penalty
Initial $3,978 · Current $2,387 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   a) Store Area: Relocated power Taps were connected in series, on or about 8/19/19
Recent events (2)
  • — I (S) $2386.8
  • — Z (S) $3978

1910.304 F02 II

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 20, 2019
Penalty
Initial $5,304 · Current $3,182 Reduced
29 CFR 1910.304(f)(2)(ii): Each protective device shall be capable of detecting and interrupting all values of current that can occur at its location in excess of its trip setting or melting point;   a) Store Area: Employees were exposed to fire hazards and electric shock while working in an area where an electric breaker  was locked in the closed position, on or about 8/19/19
Recent events (2)
  • — I (S) $3182.4
  • — Z (S) $5304

1910.304 G05

Serious Gravity 1 1 instance 10 exposed
Issued
Nov 20, 2019
Penalty
Initial $3,978 · Current $2,387 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a) Store Area: Employees were exposed to electric shock while utilizing a standing fan energized by an electric extension cord without a ground connection, on or about 8/19/19
Recent events (2)
  • — I (S) $2386.8
  • — Z (S) $3978

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344308028.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.