TYLER, TX —
OSHA Inspection: MANUEL CHAVEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MANUEL CHAVEZ in 7615 LAKESIDE LN., TYLER, TX 75707 (NAICS 238310). OSHA activity number 344309729.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MANUEL CHAVEZ
- Site address
- 7615 LAKESIDE LN.
- City
- TYLER
- State
- TX
- ZIP
- 75707
- Mailing
- 106 FM 2131, WINONA, TX 75792
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.100 A
- Issued
- Oct 10, 2019
- Abate by
- Nov 6, 2019
- Penalty
- Initial $2,273 · Current $2,273
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, shall be protected by protective helmets: (a) On or about September 10, 2019 employees at the site were exposed to struck-by hazards when plastering beneath other workers on scaffolds without protective headgear.
Recent events (1)
- — Z (S) $2273
1926.451 C02
- Issued
- Oct 10, 2019
- Abate by
- Nov 6, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: (a) On or about September 10, 2019 at the site employees were exposed to fall hazards while working from a scaffold assemble which did not bear on base plates.
Recent events (1)
- — Z (S) $2842
1926.452 C02
- Issued
- Oct 10, 2019
- Abate by
- Nov 6, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: (a) On or about September 10, 2019 at the site employees were exposed to fall hazards while working from scaffolding which was not braced to secure vertical members.
Recent events (1)
- — Z (S) $2842
More inspections at Manuel Chavez
View Manuel Chavez's full OSHA safety record →
More inspections in this industry (NAICS 238310)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344309729.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.