2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: THE BOAT STORE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of THE BOAT STORE in 1907 CENTER STREET, CATLETTSBURG, KY 41129 (NAICS 488390). OSHA activity number 344319769.

Watch THE Boat Store — free Get an email when a new federal OSHA severe-injury report for THE Boat Store is published. One employer, no account, unsubscribe in one click.
Establishment
THE BOAT STORE
Site address
1907 CENTER STREET
City
CATLETTSBURG
State
KY
ZIP
41129
Mailing
PO BOX 626, CATLETTSBURG, KY 41129
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488390
Employees
4
Ownership type
A

13 citations on file for this inspection.

1910.303 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2842.00 · Current $1450.00 Reduced
29 CFR 1910.303(b)(1): Examination. Electric equipment was not free from recognized hazards that are likely to cause death or serious physical harm to employees:    a)  Vessel, rear of vessel adjacent rear door, 1907 Center Street, Catlettsburg, KY: On or about 18 Sep 2019 flexible conduit housing energized electrical conductors were hanging down from the ceiling exposing workers to electrical shock hazards.      b)  Vessel, shore side, walk in freezer, 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, cord connecting condenser controls to condenser has exposed wiring exposing workers to shock.
Recent events (2)
  • — I (S) $1450
  • — Z (S) $2842

1910.305 B01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2842.00 · Current $1450.00 Reduced
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed.    29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective.    a)  Vessel entrance, directly off gangway on right side prior to entering vessel , 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, the portable flexible extension cord was not grounded exposing workers to an electrical hazard.    b)  Vessel entrance, at rear of vessel , 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, the flexible extension cord at rear of vessel was not grounded exposing workers to an electrical hazard.
Recent events (2)
  • — I (S) $1450
  • — Z (S) $2842

1910.303 B01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment.  a) Vessel, shore side, 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, cover on right side of chest freezer missing exposing workers to electrical shock.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.304 G05

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2842.00 · Current $1450.00 Reduced
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective.    a)  Vessel entrance, directly off gangway on right side prior to entering vessel , 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, the portable flexible extension cord was not grounded exposing workers to an electrical hazard.    b)  Vessel entrance, at rear of vessel , 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, the flexible extension cord at rear of vessel was not grounded exposing workers to an electrical hazard.
Recent events (2)
  • — I (S) $1450
  • — Z (S) $2842

1910.305 A02 X

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $3410.00 · Current $1725.00 Reduced
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points:       a) Vessel, upstream at vessel, 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, an electrical extension cord at rear of vessel had exposed conductors exposing workers to electrical shock.
Recent events (2)
  • — I (S) $1725
  • — Z (S) $3410

1910.305 B01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2842.00 · Current $1450.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed:    a) Vessel, electrical control room, 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, the electrical switch providing power to the milk cooler had unused open knockouts on the side exposing energized electric parts.    b) Vessel, electrical control room, 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, the black electrical box connected to a knife switch had unused open knockouts on the bottom exposing energized electric parts.
Recent events (2)
  • — I (S) $1450
  • — Z (S) $2842

1915.81 A04

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $3978.00 · Current $2000.00 Reduced
29 CFR 1915.81(a)(4): The employer did not maintain easy and open access to each fire-alarm box, fire-call station, fire-fighting equipment, and each exit, including ladders, staircases, scaffolds, and gangways.    a)  Vessel, opposite of shore side freezer, 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, the walk in freezer did not have panic door opening handle exposing workers to serious hazard of hypothermia.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3978

1915.158 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $2842.00 · Current $1450.00 Reduced
29 CFR 1915.158(b)(2): On floating vessels under 200 feet (61 m) in length, at least one 30-inch (0.76 m) U.S. Coast Guard approved ring life buoy with line attached was not located at the gangway.    a)  Vessel, located at 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, one 30" life ring was not available on the vessel of less than 200' on the gangway.
Recent events (2)
  • — I (S) $1450
  • — Z (S) $2842

1910.157 E01

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $319.00 · Current $175.00 Reduced
29 CFR 1910.157(e)(1): The employer was not responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace:       a) Vessel, opposite of shore side freezer, 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019,  the fire extinguisher was last inspected in August 2017.
Recent events (2)
  • — I (O) $175
  • — Z (O) $319

1910.304 G05

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective.   a) Vessel - Middle of vessel outside of walk in freezer area located at 1907 Center Street, Catlettsburg, KY: On or about 18 Sep 2019, the flexible armored steel conduit was damaged exposing insulated conductors exposing workers to electrical shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.304 F01 IV

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.304(f)(1)(iv): Overcurrent devices were not readily accessible to each employee or authorized building management personnel.    a)  Vessel, riverside, 1907 Center Street, Catlettsburg, KY: On or about 18 Sep 2019, an electrical panel box was blocked with grocery items and boxes preventing workers access to electrical panel.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G02 III

Other-than-serious 4 instances 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws:   a)  Vessel, down stream at rear of vessel, 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, the power cord on the Pepsi machine was pulled free from the plug exposing insulated conductors exposing workers to electrical shock.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1915.87 F01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1915.87(f)(1): The employer did not provide an adequate number of basket stretchers, or the equivalent, readily accessible to where work is being performed on a vessel or vessel section.    a)  Vessel, located at 1907 Center Street, Catlettsburg, KY, on or about 18 Sep 2019, stokes basket was not available to workers while performing duties on vessel.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0