CATLETTSBURG, KY —
OSHA Inspection: THE BOAT STORE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of THE BOAT STORE in 1907 CENTER STREET, CATLETTSBURG, KY 41129 (NAICS 488390). OSHA activity number 344319769.
Where did this inspection happen?
- Establishment
- THE BOAT STORE
- Site address
- 1907 CENTER STREET
- City
- CATLETTSBURG
- State
- KY
- ZIP
- 41129
- Mailing
- PO BOX 626, CATLETTSBURG, KY 41129
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488390
- Employees
- 4
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.303 B01
- Issued
- Penalty
- Initial $2842.00 · Current $1450.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Examination. Electric equipment was not free from recognized hazards that are likely to cause death or serious physical harm to employees: a) Vessel, rear of vessel adjacent rear door, 1907 Center Street, Catlettsburg, KY: On or about 18 Sep 2019 flexible conduit housing energized electrical conductors were hanging down from the ceiling exposing workers to electrical shock hazards. b) Vessel, shore side, walk in freezer, 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, cord connecting condenser controls to condenser has exposed wiring exposing workers to shock.
Recent events (2)
- — I (S) $1450
- — Z (S) $2842
1910.305 B01 I
- Issued
- Penalty
- Initial $2842.00 · Current $1450.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. 29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective. a) Vessel entrance, directly off gangway on right side prior to entering vessel , 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, the portable flexible extension cord was not grounded exposing workers to an electrical hazard. b) Vessel entrance, at rear of vessel , 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, the flexible extension cord at rear of vessel was not grounded exposing workers to an electrical hazard.
Recent events (2)
- — I (S) $1450
- — Z (S) $2842
1910.303 B01 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(1)(ii): Electrical equipment was not free from recognized hazards, based on the mechanical strength and durability, including, for parts designed to enclose and protect other equipment. a) Vessel, shore side, 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, cover on right side of chest freezer missing exposing workers to electrical shock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 G05
- Issued
- Penalty
- Initial $2842.00 · Current $1450.00 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective. a) Vessel entrance, directly off gangway on right side prior to entering vessel , 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, the portable flexible extension cord was not grounded exposing workers to an electrical hazard. b) Vessel entrance, at rear of vessel , 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, the flexible extension cord at rear of vessel was not grounded exposing workers to an electrical hazard.
Recent events (2)
- — I (S) $1450
- — Z (S) $2842
1910.305 A02 X
- Issued
- Penalty
- Initial $3410.00 · Current $1725.00 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points: a) Vessel, upstream at vessel, 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, an electrical extension cord at rear of vessel had exposed conductors exposing workers to electrical shock.
Recent events (2)
- — I (S) $1725
- — Z (S) $3410
1910.305 B01 II
- Issued
- Penalty
- Initial $2842.00 · Current $1450.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed: a) Vessel, electrical control room, 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, the electrical switch providing power to the milk cooler had unused open knockouts on the side exposing energized electric parts. b) Vessel, electrical control room, 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, the black electrical box connected to a knife switch had unused open knockouts on the bottom exposing energized electric parts.
Recent events (2)
- — I (S) $1450
- — Z (S) $2842
1915.81 A04
- Issued
- Penalty
- Initial $3978.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1915.81(a)(4): The employer did not maintain easy and open access to each fire-alarm box, fire-call station, fire-fighting equipment, and each exit, including ladders, staircases, scaffolds, and gangways. a) Vessel, opposite of shore side freezer, 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, the walk in freezer did not have panic door opening handle exposing workers to serious hazard of hypothermia.
Recent events (2)
- — I (S) $2000
- — Z (S) $3978
1915.158 B02
- Issued
- Penalty
- Initial $2842.00 · Current $1450.00 Reduced
General-duty citation text
29 CFR 1915.158(b)(2): On floating vessels under 200 feet (61 m) in length, at least one 30-inch (0.76 m) U.S. Coast Guard approved ring life buoy with line attached was not located at the gangway. a) Vessel, located at 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, one 30" life ring was not available on the vessel of less than 200' on the gangway.
Recent events (2)
- — I (S) $1450
- — Z (S) $2842
1910.157 E01
- Issued
- Penalty
- Initial $319.00 · Current $175.00 Reduced
General-duty citation text
29 CFR 1910.157(e)(1): The employer was not responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace: a) Vessel, opposite of shore side freezer, 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, the fire extinguisher was last inspected in August 2017.
Recent events (2)
- — I (O) $175
- — Z (O) $319
1910.304 G05
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent, continuous, and effective. a) Vessel - Middle of vessel outside of walk in freezer area located at 1907 Center Street, Catlettsburg, KY: On or about 18 Sep 2019, the flexible armored steel conduit was damaged exposing insulated conductors exposing workers to electrical shock hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.304 F01 IV
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.304(f)(1)(iv): Overcurrent devices were not readily accessible to each employee or authorized building management personnel. a) Vessel, riverside, 1907 Center Street, Catlettsburg, KY: On or about 18 Sep 2019, an electrical panel box was blocked with grocery items and boxes preventing workers access to electrical panel.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G02 III
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws: a) Vessel, down stream at rear of vessel, 1907 Center Street, Catlettsburg, KY, On or about 18 Sep 2019, the power cord on the Pepsi machine was pulled free from the plug exposing insulated conductors exposing workers to electrical shock.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1915.87 F01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1915.87(f)(1): The employer did not provide an adequate number of basket stretchers, or the equivalent, readily accessible to where work is being performed on a vessel or vessel section. a) Vessel, located at 1907 Center Street, Catlettsburg, KY, on or about 18 Sep 2019, stokes basket was not available to workers while performing duties on vessel.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 488390)
WARROAD, MN—2026-05-19
U.S. COAST GUARD SECTOR NORTHERN GREAT LAKES
HOUMA, LA—2026-04-27
AMERICAN RECOVERY LLC
TAOS, NM—2026-03-31
TAOS, TOWN OF
SEATTLE, WA—2026-01-26
WA317989551 - VIGOR INDUSTRIAL LLC
PORTLAND, OR—2025-12-11
DEPT. OF DEFENSE - USACE
More inspections in KY
RICHARDSVILLE, KY—2026-07-10
69312 - SIEGRIST SERVICE COMPANY LLC
NEWPORT, KY—2026-07-10
69309 - NORTHERN KENTUCKY UNIVERSITY
DANVILLE, KY—2026-07-09
69313 - TRANSNAV TECHNOLOGIES INC
LEXINGTON, KY—2026-07-09
69310 - DAVIS H ELLIOT COMPANY INC
WINCHESTER, KY—2026-07-09
69311 - KENTUCKY FERTILIZER LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344319769.