Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: KENNEDY GALVANIZING, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of KENNEDY GALVANIZING, INC. in 301 INDUSTRIAL BLVD., HANCEVILLE, AL 35077 (NAICS 332812). OSHA activity number 344319892.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kennedy Galvanizing, INC. — free Get an email when a new federal OSHA severe-injury report for Kennedy Galvanizing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
301 INDUSTRIAL BLVD.
City
HANCEVILLE
State
AL
ZIP
35077
Mailing
301 INDUSTRIAL BLVD., HANCEVILLE, AL 35077
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
18
Ownership type
A

8 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 16, 2020
Abate by
Apr 20, 2020
Penalty
Initial $4,164 · Current $2,498 Reduced

Hazardous substances 8111

29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:  (a) On or about September 19, 2019 - Finishing area, a finisher was exposed to continuous noise levels at 100% of the allowable 8-hour time-weighted average level (TWA) or an equivalent level of approximately 90 dBA.  The sampling was conducted for 474 minutes during one shift on October 23, 2019.  Zero exposure was assumed for the unsampled time of 26 minutes.
Recent events (2)
  • — I (S) $2498.4
  • — Z (S) $4164

1910.95 G01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 16, 2020
Abate by
Apr 9, 2020
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided by 29 CFR 1910.95(g) by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels:     (a) On or about September 19, 2019 - Finishing area, a finisher was exposed to continuous noise levels at 100% of the allowable 8-hour time-weighted average level (TWA) or an equivalent level of approximately 90 dBA. The sampling was conducted for 474 minutes during one shift on October 23, 2019.  Zero exposure was assumed for the unsampled time of 26 minutes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.95 I03

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 16, 2020
Abate by
Apr 9, 2020
Penalty
Initial $0 · Current $0

Hazardous substances 8111

29 CFR 1910.95(i)(3): Employees were not given the opportunity to select their hearing protectors from a variety of suitable hearing protectors provided by the employer:  (a) On or about September 19, 2019 - Finishing area, the employer did not provide a variety of hearing protectors to employees.  A finisher was exposed to continuous noise levels at 100% of the allowable 8-hour time-weighted average level (TWA) or an equivalent level of approximately 90 dBA.  The sampling was conducted for 474 minutes during one shift on October 23, 2019.  Zero exposure was assumed for the unsampled time of 26 minutes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 16, 2020
Abate by
Apr 9, 2020
Penalty
Initial $2,776 · Current $1,666 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  (a) On or about September 19, 2019 - Dipping area, an emergency eyewash/shower station was not provided for employees exposed to corrosive materials such as, but not limited to, Hydrochloric Acid.
Recent events (2)
  • — I (S) $1665.6
  • — Z (S) $2776

1910.184 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 16, 2020
Abate by
Apr 9, 2020
Penalty
Initial $4,164 · Current $2,498 Reduced
29 CFR 1910.184(c)(2): Slings shall not be shortened with knots or bolts or other makeshift devices:  (a) On or about September 19, 2019 - Dipping area, slings, used for moving of metal parts, were shortened with knots.
Recent events (2)
  • — I (S) $2498.4
  • — Z (S) $4164

1910.141 B01 III

Other-than-serious 1 instance 5 exposed
Issued
Mar 16, 2020
Abate by
Mar 26, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.141(b)(1)(iii): Portable drinking water dispensers were not designed, constructed, and serviced so that sanitary conditions are maintained:  (a) On or about September 19, 2019 - Finishing area, a spigot on a 5-gallon Igloo beverage cooler was not maintained clean.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E03

Other-than-serious 1 instance 18 exposed
Issued
Mar 16, 2020
Abate by
Apr 9, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  (a) On or about September 19, 2019 - Facility, fire extinguishers were not inspected annually.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 18 exposed
Issued
Mar 16, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  (a) On or about September 19, 2019 - Facility, a written hazard communication had not been developed and implemented for employees working with chemicals such as, but not limited to, Hydrochloric Acid and Special High Grade Zinc.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Kennedy Galvanizing, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344319892.