PORT ARANSAS, TX —
OSHA Inspection: MARCIEL ALVARADO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MARCIEL ALVARADO in 728 MIRA MAR LANE, PORT ARANSAS, TX 78373 (NAICS 236118). OSHA activity number 344322672.
Where did this inspection happen?
- Establishment
- MARCIEL ALVARADO
- Site address
- 728 MIRA MAR LANE
- City
- PORT ARANSAS
- State
- TX
- ZIP
- 78373
- Mailing
- 829 ROSSI DRIVE, CORPUS CHRISTI, TX 78411
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.404 F06
- Issued
- Penalty
- Initial $1475.00 · Current $1475.00
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: At this work site, the ground prong was missing on the extension cord powering the saw.
Recent events (1)
- — Z (S) $1475
1926.1051 A
- Issued
- Abate by
- Penalty
- Initial $1735.00 · Current $1735.00
General-duty citation text
29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided: At this worksite, the employer did not provide a safe means of access for an employee going from the second story balcony top rail to the balcony walking/working surface.
Recent events (1)
- — Z (S) $1735
1926.1053 B10
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(10): The top of a non-self-supporting ladder was not placed with the two rails supported equally, nor was it equipped with a single support attachment: At this worksite, an employee was permitted to use an extension ladder to access the second story balcony without the side rails being evenly supported.
Recent events (1)
- — Z (S) $0
1926.405 G02 IV
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: At this site, the flexible cord powering an air compressor and saw was not connected with a functional strain relief device.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 236118)
BROOKLYN, NY—2026-07-15
MEGA GENERAL CONSTRUCTION NYC INC.
BROOKLYN, NY—2026-07-15
MEGA GENERAL CONSTRUCTION NYC INC.
SYRACUSE, NY—2026-07-14
EMPIRE BUILDERS OF CNY, INC.
RENTON, WA—2026-07-14
WA317992055 - JCC INVESTMENT GROUP LLC
RIVERTON, NJ—2026-07-14
JBF CONSTRUCTION LLC
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.