Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MODERN BUILDERS SUPPLY INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MODERN BUILDERS SUPPLY INC. in 45 KARAGO AVE., BOARDMAN, OH 44513 (NAICS 326199). OSHA activity number 344323829.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Modern Builders Supply INC. — free Get an email when a new federal OSHA severe-injury report for Modern Builders Supply INC. is published. One employer, no account, unsubscribe in one click.
Site address
45 KARAGO AVE.
City
BOARDMAN
State
OH
ZIP
44513
Mailing
45 KARAGO AVE., BOARDMAN, OH 44513
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
64
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II B

Other-than-serious 1 instance 3 exposed
Issued
Jan 27, 2020
Abate by
Mar 13, 2020
Penalty
Initial $7,711 · Current $0 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:       On or about September 20, 2019, although the employer established a program for the control of hazardous energy, it was deficient in that; the scope and purpose, and a specific statement of the intended use were missing. The employer also failed to identify the hazardous energy sources which needed to be render safe, therefore specificity of written procedures for machinery such as, but not limited to, the door router machinery was missing.  Energy sources used at the facility include, but are not limited to; electricity, pneumatic energy and gravity.
Recent events (2)
  • — I (O) $0
  • — Z (S) $7711

1910.212 A01

Serious Gravity 10 14 instances 2 exposed
Issued
Jan 27, 2020
Abate by
Sep 30, 2020
Penalty
Initial $13,494 · Current $10,795 Reduced
1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.      On or about September 20, 2019, the employer did not ensure that various equipment or machinery used at the site was effectively guarded.  The unguarded equipment includes; but is not limited to, the following:     a. The three (3) punch presses located in the Framing department were not adequately guarded. The affixed guarding had a gap of approximately 1-1.8125 inches, and did not effectively protect the operator from potential hazards created by the moving/rotating part(s).      b. The ten (10) punch presses that were a part of the Patio Door line were not adequately guarded. The affixed guarding had gaps that varied between 1-5 1/8 inches. Operators were potentially exposed to hazards created by the struck by, caught-by or moving/rotating part(s).      c. The one (1) single pallet wrapping machine located at the Patio Door line was unguarded and did not prevent operators from having any part of their bodies in the danger zone during operation. Employees tasked with operating the machinery are exposed to potential rotating and/or caught by hazards.
Recent events (2)
  • — I (S) $10795
  • — Z (S) $13494

1910.213 H01

Serious Gravity 5 2 instances 2 exposed
Issued
Jan 27, 2020
Abate by
Feb 21, 2020
Penalty
Initial $9,639 · Current $7,711 Reduced
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the stock being cut to give maximum protection possible for the operation being performed:    On and before September 20, 2019, the lower exposed portion of the company's Delta (900 and Shop Master) radial saws was not equipped with a device that automatically adjust itself to the thickness of the stock. Employees who used the saws when cutting headers for door frames or other wood working activities were not protected from inadvertently contacting the rotating saw blade.
Recent events (2)
  • — I (S) $7711
  • — Z (S) $9639

1910.1200 F06

Deleted Serious Gravity 5 5 instances 2 exposed
Issued
Jan 27, 2020
Abate by
Feb 10, 2020
Penalty
Initial $7,711 · Current $0 Reduced
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:   On or about September 20, 2019, the employer failed to ensure that denatured alcohol, which had been removed from its original container and placed into emptied paint cans was re-labeled to identify the new contents.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7711