APPLETON, WI —
OSHA Inspection: SCHOENECKER STEEL ROOFING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SCHOENECKER STEEL ROOFING, LLC in 3131 BLUETOPAZ DR., APPLETON, WI 54913 (NAICS 238160). OSHA activity number 344324272.
Where did this inspection happen?
- Establishment
- SCHOENECKER STEEL ROOFING, LLC
- Site address
- 3131 BLUETOPAZ DR.
- City
- APPLETON
- State
- WI
- ZIP
- 54913
- Mailing
- E1571 STRATTON LAKE RD., WAUPACA, WI 54981
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.20 B01
- Issued
- Abate by
- Penalty
- Initial $2273.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): It shall be the responsibility of the employer to initiate and maintain such programs as may be necessary to comply with this part. The employer did not maintain accident prevention programs to ensure compliance with construction industry hazards such as fall hazard training program, and scaffold safety training program.
Recent events (2)
- — I (S) $0
- — Z (S) $2273
1926.454 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $1137.00
General-duty citation text
29 CFR 1926.454(b): The employer shall have each employee who is involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question. The training shall include the following topics, as applicable; the nature of scaffold hazards; the correct procedures for erecting, disassembling, moving, operating, repairing, inspecting, and maintaining the type of scaffold in questions; the design criteria, maximum intended load-carrying capacity and intended use of the scaffold; any other pertinent requirements of this standard: The employer did not ensure employees engaged in erecting, disassembling, moving, and working from a tubular welded frame scaffolding to install steel roofing and siding were trained in the nature of scaffold hazards, the correct procedures for erecting, disassembling, moving, operating, repairing, inspection and maintaining the scaffold, the maximum intended load-carrying capacity, and the intended use of the scaffold.
Recent events (2)
- — I (S) $1136.5
- — Z (S) $0
1926.503 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards. The employer did not develop a fall protection training program for employees exposed to fall hazards while engaging in residential and commercial steel roofing and siding activities.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 B01
- Issued
- Penalty
- Initial $2273.00 · Current $1137.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: On or about September 18, 2019, employees utilized a tubular welded frame scaffolding to install standing seam metal roofing and access the patio roof surface located at 3131 Bluetopaz Dr. Appleton, WI without fully planking or decking the working level of the scaffold.
Recent events (2)
- — I (S) $1136.5
- — Z (S) $2273
1926.451 C02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. On or about September 18, 2019, employees utilized a tubular welded frame scaffolding to install standing seam metal roofing and to access the patio roof located at 3131 Bluetopaz Dr. Appleton, WI. The scaffolding had three caster wheels and a screw jack on soil ground without base plates or mud sills to provide a firm adequate foundation.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. On or about September 18, 2019, employees working from a tubular welded frame scaffolding were exposed to fall hazards of over 10 feet without any form of fall protection while installing standing seam metal roofing on a patio roof located at 3131 Bluetopaz Dr. Appleton, WI.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. On or about September 18, 2019, employees working from a patio roof located at 3131 Bluetopaz Dr. Appleton, WI were exposed to fall hazards of approximately 11.5 feet without any form of fall protection while installing standing seam metal roofing. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344324272.