MASON, OH —
OSHA Inspection: REGINALDO MARTINEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of REGINALDO MARTINEZ in 406 4TH ST., MASON, OH 45040 (NAICS 238160). OSHA activity number 344325451.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REGINALDO MARTINEZ
- Site address
- 406 4TH ST.
- City
- MASON
- State
- OH
- ZIP
- 45040
- Mailing
- 1165 CHESTER ROAD, CINCINNATI, OH 45246
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B10
- Issued
- Oct 29, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $3,978 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): "Roofing work on Low-slope roofs." Except as otherwise provided in paragraph (b) of this section, each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width (see Appendix A to subpart M of this part), the use of a safety monitoring system alone [i.e. without the warning line system] is permitted. On September 19, 2019, at 406 4th St. Mason, a church building, roofers were installing a new roof membrane on a low-slope roof and exposed to a 20 ft. fall hazard without utilizing any fall protection.
Recent events (2)
- — I (S) $2000
- — Z (S) $3978
1926.1053 B01
- Issued
- Oct 29, 2019
- Penalty
- Initial $2,842 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On September 19, 2019, at 406 4th St. Mason, a church building, roofers were exposed to a fall hazard when using a single metal ladder to access the roof and the ladder extended approximately 12 inches above the eave of the roof.
Recent events (2)
- — I (S) $0
- — Z (S) $2842
1926.1053 B16
- Issued
- Oct 29, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, shall either be immediately marked in a manner that readily identifies them as defective, or be tagged with "Do Not Use" or similar language, and shall be withdrawn from service until repaired. On September 19, 2019, at 406 4th Street, a church building, roofers were using a single metal ladder to ascend and descend from the low-slope roof was missing a rung at the 2nd from the top of the ladder and the ladder was not removed from service until repaired.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238160)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344325451.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.