BROOK PARK, OH —
OSHA Inspection: WAELZHOLZ NORTH AMERICA, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WAELZHOLZ NORTH AMERICA, LLC in 5221 WEST 164TH STREET, BROOK PARK, OH 44142 (NAICS 423510). OSHA activity number 344326863.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- WAELZHOLZ NORTH AMERICA, LLC
- Site address
- 5221 WEST 164TH STREET
- City
- BROOK PARK
- State
- OH
- ZIP
- 44142
- Mailing
- 5221 WEST 164TH STREET, BROOK PARK, OH 44142
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423510
- Employees
- 23
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.25 B03
- Issued
- Dec 16, 2019
- Penalty
- Initial $3,031 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.25(b)(3): The employer did not ensure that the stairs had uniform riser heights and tread depths between the landings: On or about September 23, 2019, employees were exposed to two sets of steps that were not uniform at the 52 inch slitter line. The east side steps had three risers measuring 10 inches, 9 inches, 9 inches and the north steps had three risers measuring 8 inches, 9 inches and 10 inches. The employer did not ensure stairs had uniform riser heights.
Recent events (2)
- — I (S) $1500
- — Z (S) $3031
1910.147 C06 I
- Issued
- Dec 16, 2019
- Penalty
- Initial $3,031 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about September 23, 2019, the employer did not ensure periodic inspection of their lockout tagout procedures were conducted within the past 12 months.
Recent events (2)
- — I (S) $1500
- — Z (S) $3031
1910.212 A01
- Issued
- Dec 16, 2019
- Abate by
- Oct 6, 2020
- Penalty
- Initial $3,789 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about September 23, 2019, the employer did not ensure the following machinery was properly safeguarded. 1. 20 inch slitter line, drive side un-coiler, leveler, pinch rolls, shear, stringer baler and re-coiler. 2. 24 inch slitter line, drive side un-coiler, leveler, pinch rolls, shear, stringer baler and re-coiler. 3. 52 inch slitter line, operator side and drive side un-coiler, leveler, pinch rolls, shear, stringer baler and re-coiler. 4. Oscillator line, operator and drive side from the un-coiler through the butt welder and leveler to the re-coiler. 5. Ski Edge area, cut to length line and bending machinery operator and drive side un-coiler, leveler, pinch roll, shear.
Recent events (2)
- — I (S) $3000
- — Z (S) $3789
1910.219 I02
- Issued
- Dec 16, 2019
- Abate by
- Jan 27, 2020
- Penalty
- Initial $3,031 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.219(i)(2): Revolving surfaces of shaft coupling(s) were not covered by a safety sleeve: On or about September 23, 2019, the employer did not ensure the rotating coupling on the horizontal shaft between the drive motor and gearbox for the entry un-coiler of the 24 inch slitter line was guarded.
Recent events (2)
- — I (S) $3000
- — Z (S) $3031
1910.242 B
- Issued
- Dec 16, 2019
- Penalty
- Initial $3,031 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about September 23, 2019, the employer did not ensure compressed air used for cleaning was less than 30psi. The flexible hose compressed airline with a quick open valve and nozzle that was being used for cleaning at the ski edge area bending machine was set at 50psi.
Recent events (2)
- — I (S) $3000
- — Z (S) $3031
1910.305 B01 II
- Issued
- Dec 16, 2019
- Penalty
- Initial $3,031 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about September 23, 2019, there were two areas where electrical control boxes had unused openings and the employer did not ensure they were effectively closed. 1. On the north wall at the ski edge area there was an electrical disconnect switch labeled (Cut To Length Line - 240 Volts) with an unused opening at the bottom of the box. 2. On the west wall at the 24 inch slitter line re-coiler there was an electrical control box labeled (Cold Mill 220V) with two unused openings in the side of the box.
Recent events (2)
- — I (S) $1500
- — Z (S) $3031
1910.305 B02 I
- Issued
- Dec 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: On or about September 23, 2019, there was an electrical junction box positioned on the work floor at the drive side of the Ideal butt welder of the Oscillator line. The cover for the large electrical box was ajar and not secured.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B04 III
- Issued
- Dec 16, 2019
- Penalty
- Initial $3,031 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet: On or about September 23, 2019, at the northwest corner of the building there were oxygen and acetylene cylinders stored in the same expanded metal cage. There was a cutting torch cart that contained an oxygen cylinder and acetylene cylinder with hoses, gages and a hand torch along with a separate oxygen cylinder and a separate acetylene cylinder that were chained on the inside of the cage.
Recent events (2)
- — I (S) $1500
- — Z (S) $3031
1910.253 E01
- Issued
- Dec 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(e)(1): Equipment was not installed and used only in the service for which it was approved and as recommended by the manufacturer: On or about September 23, 2019, the oxygen and acetylene cylinder pressure regulators for the hoses and cutting torch had gage lenses that were missing.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Dec 16, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: On or about September 23, 2019, in the QS supply room the electrical power strip for the vending machines was of commercial grade and not secured.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Waelzholz North America, LLC
View Waelzholz North America, LLC's full OSHA safety record →
More inspections in this industry (NAICS 423510)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344326863.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.