Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DAMIEN VASQUEZ

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DAMIEN VASQUEZ in 401 CROWN AVE, SCRANTON, PA 18505 (NAICS 238160). OSHA activity number 344332853.

Watch Damien Vasquez — free Get an email when a new federal OSHA severe-injury report for Damien Vasquez is published. One employer, no account, unsubscribe in one click.
Establishment
DAMIEN VASQUEZ
Site address
401 CROWN AVE
City
SCRANTON
State
PA
ZIP
18505
Mailing
1018 N. MAIN ST. APT #1, SCRANTON, PA 18508
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1705.00 · Current $1705.00
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a) 401 Crown Ave., Scranton, PA: Employees working below areas where roofing work was taking place were not protected from falling tools and material by a protective helmet, on or about September 25, 2019.  ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $1705

1926.404 B01 II

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1705.00 · Current $1705.00
29 CFR 1926.404(b)(1)(ii): Ground-fault circuit interrupters. All 120-volt, single-phase 15- and 20-ampere receptacle outlets on construction sites, which are not a part of the permanent wiring of the building or structure and which are in use by employees, did not have approved ground-fault circuit interrupters for personnel protection:  a) 401 Crown Avenue, Scranton, PA: The employer did not provide ground fault circuit interrupters for extension cords connected to exterior 110 volt receptacles exposing employees to the potential for an electric shock, on or about September 25, 2019.  ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $1705

1926.501 B13

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $2273.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a) 401 Crown Avenue, Scranton, PA: Employees performing roofing work on a steep roof with a potential fall of approximately 20 feet were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were the employees provided with an alternative fall protection measure, discovered on or about September 25, 2019.   b) 401 Crown Avenue, Scranton, PA: Employees performing roofing work on a porch roof with a potential fall of approximately 12 feet were not protected from falling by a guardrail system, safety net system, or personal fall arrest system, nor were the employees provided with an alternative fall protection measure, discovered on or about September 25, 2019.  ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $2273

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2273.00 · Current $2273.00
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface, the ladder side rails did not extend at least 3 feet (0.9 m) above the upper landing surface being accessed and the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder:  a) 401 Crown Avenue, Scranton, Pa: An employee performing roofing work on a steep roof was utilizing a portable ladder that was not extended at least 3 feet above the upper landing surface of a roof, on or about September 25, 2019.  ABATEMENT CERTIFICATION REQUIRED
Recent events (1)
  • — Z (S) $2273

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344332853.