OSHA Inspection: VOGAN MANUFACTURING

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of VOGAN MANUFACTURING in 316 VOGANVILLE RD., NEW HOLLAND, PA 17557 (NAICS 332618). OSHA activity number 344350889.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vogan Manufacturing — free Get an email when a new federal OSHA severe-injury report for Vogan Manufacturing is published. One employer, no account, unsubscribe in one click.
Establishment
VOGAN MANUFACTURING
Site address
316 VOGANVILLE RD.
City
NEW HOLLAND
State
PA
ZIP
17557
Mailing
316 VOGANVILLE RD., NEW HOLLAND, PA 17557
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332618
Employees
6
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 3 instances 3 exposed
Issued
Oct 10, 2019
Abate by
Nov 6, 2019
Penalty
Initial $3,978 · Current $3,978
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points and rotating parts:  a) 316 Voganville Road - The employer did not ensure that the Wafios CNC machine BM 51 L Serial # 2-7566-006 was properly guarded to protect operators from reaching in the compartment during operation. The limit switches designed to stop the machine if the lid is opened were disabled, on or about October 2, 2019.   b) 316 Voganville Road - The employer did not ensure that the Wafios CNC machine BM 4 Serial # 2-7552-119  was properly guarded to protect operators from reaching in the compartment during operation. The limit switches designed to stop the machine if the lid is opened were disabled, on or about October 2, 2019.   c) 316 Voganville Road - The employer did not ensure that the Wafios CNC machine BM 40 Serial # 2-7658-037 was properly guarded to protect operators from reaching in the compartment during operation. The limit switches designed to stop the machine if the lid is opened were disabled, on or about October 2, 2019.   Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $3978
  • — Z (S) $3978

1910.147 C01

Serious Gravity 10 3 instances 3 exposed
Issued
Oct 10, 2019
Abate by
Jan 3, 2020
Penalty
Initial $3,978 · Current $0 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    a) 316 Voganville Road - The employer did not ensure that they had the required energy control program to prevent employees from unexpected start-up or release of energy that could cause injury to employees who have performed maintenance on the Wafios CNC machines BM 51 L 2-7566-006, BM 4 2-7522-119 and BM 40 2-7658-037, on or about October 2, 2019.    Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3978

1910.147 C04 I

Serious Gravity 10 3 instances 3 exposed
Issued
Oct 10, 2019
Abate by
Jan 3, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a) 316 Voganville Road - The company did not have a specific lock out tag out procedure for the Wafios CNC machine model# BM 51 L- serial# 2-7566-006 which had multiple energy sources including but not limited to: Hydraulic, Pneumatic and electric on or about October 2, 2019.    b) 316 Voganville Road - The company did not have a specific lock out tag out procedure for the Wafios CNC machine model# BM 4  serial# 2-7522-119 which had multiple energy sources including but not limited to: Hydraulic, Pneumatic and electric on or about October 2, 2019.    c)  316 Voganville Road - The company did not have a specific lock out tag out procedure  procedure for the Wafios CNC machine model# BM40,  serial# 2-7658-037 which had multiple energy sources including but not limited to: Hydraulic, Pneumatic and electric on or about October 2, 2019.    Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 I

Serious Gravity 5 1 instance 6 exposed
Issued
Oct 10, 2019
Abate by
Jan 3, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:    a) 316 Voganville Road - The employer did not have a written energy control written program or procedures, therefore the Authorized, Effected and Other employees were not trained on the purpose and function of the energy control program and authorized employees did not have the knowledge and skills to safely conduct lock out tag out on or about October 2, 2019.    Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0