Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HARVEY BUILDERS

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of HARVEY BUILDERS in 8701 FM 2244, AUSTIN, TX 78746 (NAICS 236220). OSHA activity number 344355995.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Harvey Builders — free Get an email when a new federal OSHA severe-injury report for Harvey Builders is published. One employer, no account, unsubscribe in one click.
Establishment
HARVEY BUILDERS
Site address
8701 FM 2244
City
AUSTIN
State
TX
ZIP
78746
Mailing
6710A ROCKLEDGE DRIVE, BETHESDA, MD 20817
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
Yes
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
236220
Employees
21
Ownership type
A

4 citations on file for this inspection.

1926.501 B04 II

Serious Gravity 1 1 instance 21 exposed
Issued
Mar 9, 2020
Penalty
Initial $4,684 · Current $4,684
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers.  On or about 1 October 2019, and at times prior thereto, the worksite trailer had two sets of stairs paired together that left a hole in the middle. The hole was approximately 3.5 inches wide and the depth of all four stair treads, creating a hazard of tripping or stepping into the hole.
Recent events (2)
  • — C (S) $4684
  • — Z (S) $4684

1926.602 C01 VI

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 9, 2020
Abate by
Mar 13, 2020
Penalty
Initial $7,808 · Current $7,808
29 CFR 1926.602(c)(1)(vi): Industrial truck(s) in use did not meet the applicable requirements of design, construction, stability, inspection, testing, maintenance, and operation, as defined in American National Standards Institute B56.1-1969, Safety Standards for Powered Industrial Trucks.  On or about 1 October 2019, and at times prior thereto, a forklift was used to move tools and equipment in a wooden box to the second level of a garage for unloading. The wooden box was not attached to the forklift, did not have fork pockets, did not have the tare weight identified, and was not placed up against the backstop of the carriage. The forks were not adjusted for maximum width and the load was not assessed for center and operating conditions, exposing the workers to an unstable load and struck-by hazards where operation did not account for dynamic forces.
Recent events (2)
  • — C (S) $7808
  • — Z (S) $7808

1926.251 A02 I

Other-than-serious 1 instance 21 exposed
Issued
Mar 9, 2020
Abate by
Mar 13, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.251(a)(2)(i): The employer failed to ensure rigging equipment had permanently affixed and legible identification markings as prescribed by the manufacturer that indicate the recommended safe working load.  On or about 1 October 2019, and at times prior thereto, two wire rope slings used to lift metal baskets with a crane at the site did not have permanently affixed and legible identification markings to indicate the recommended safe working load, exposing workers near the path of movement to the hazard of being struck by the basket or materials in the basket.
Recent events (2)
  • — C (O) $0
  • — Z (O) $0

1926.403 B02

Other-than-serious 1 instance 21 exposed
Issued
Mar 9, 2020
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification.   On or about 1 October 2019, and at times prior thereto, an office within the General Contractor's worksite trailer had two relocatable power taps connected in series and then connected to an extension cord that was plugged into a wall outlet, creating a potential hazard for electrical shorts, overloads and fires.
Recent events (2)
  • — C (O) $0
  • — Z (O) $0

View Harvey Builders's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344355995.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.