DENVER, CO —
OSHA Inspection: CORE CONTRACTORS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CORE CONTRACTORS, INC. in 5575 TEJON ST, DENVER, CO 80221 (NAICS 238160). OSHA activity number 344356472.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CORE CONTRACTORS, INC.
- Site address
- 5575 TEJON ST
- City
- DENVER
- State
- CO
- ZIP
- 80221
- Mailing
- 4049 ST. PAUL ST, DENVER, CO 80216
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 20
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.502 D15 II
- Issued
- Nov 14, 2019
- Abate by
- Dec 19, 2019
- Penalty
- Initial $3,031 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.502(d)(15)(ii): Anchorages used for attachment of personal fall arrest equipment was not capable of supporting at least 5,000 pounds per employee attached, and was not installed under the supervision of a qualified person: a) Core Contractors, Inc at 5575 Tejon Street, Denver, CO 80221: On or before October 03, 2019, the employer did not ensure that anchorages used for attachment of personal fall arrest equipment was capable of supporting at least 5,000 pounds per employee attached, and was installed under the supervision of a qualified person. Two employees used the same anchorage point when installing snow fences on a commercial roof. This condition exposed employees to a fall hazard of 15-17 feet.
Recent events (2)
- — I (S) $2000
- — Z (S) $3031
1926.503 A02 II
- Issued
- Nov 14, 2019
- Abate by
- Dec 19, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(2)(ii): The employer did not assure that each employee, as necessary, had been trained by a competent person in the correct procedures for erecting, maintaining, disassembling and inspecting the fall protection systems to be used: a) Core Contractors, Inc at 5575 Tejon Street, Denver, CO 80221: On or before October 03, 2019, the employer did not ensure that each employee exposed to fall hazards was trained by a competent person in the correct procedures for erecting, maintaining, disassembling and inspecting the fall protection systems to be used. Two employees were not trained on the correct use of personal fall arrest systems in that both used the same anchorage point when installing snow fences on a commercial roof. This condition exposed employees to a fall hazard of 15-17 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Core Contractors, INC.
View Core Contractors, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in CO
Source