ROCKAWAY PARK, NY —
OSHA Inspection: MAIN MAN WATER MAIN AND SEWER SERVICE LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MAIN MAN WATER MAIN AND SEWER SERVICE LLC in 169 115TH ST, ROCKAWAY PARK, NY 11694 (NAICS 237110). OSHA activity number 344356761.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAIN MAN WATER MAIN AND SEWER SERVICE LLC
- Site address
- 169 115TH ST
- City
- ROCKAWAY PARK
- State
- NY
- ZIP
- 11694
- Mailing
- 994 CLARK PLACE, WOODMERE, NY 11598
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 10
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.651 C02
- Issued
- Oct 24, 2019
- Penalty
- Initial $3,978 · Current $2,590 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: (a) At the worksite - A safe means of getting in and out of the excavation was not provided; on or about 10/03/19.
Recent events (2)
- — I (S) $2590
- — Z (S) $3978
1926.651 J02
- Issued
- Oct 24, 2019
- Penalty
- Initial $3,978 · Current $2,590 Reduced
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. (a) At the worksite - Spoils were piled adjacent to an excavation that was over 5 feet deep; on or about 10/03/19.
Recent events (2)
- — I (S) $2590
- — Z (S) $3978
1926.652 A01
- Issued
- Oct 24, 2019
- Penalty
- Initial $3,978 · Current $2,590 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). The employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i) in that the excavation was sloped at an angle steeper than one and one-half horizontal to one vertical (34 degrees measured from the horizontal): (a) At the worksite - Employees installing a sewer pipe in an excavation greater than 5 feet deep were not protected from cave-ins. The walls of the excavation were almost vertical; on or about 10/03/19.
Recent events (2)
- — I (S) $2590
- — Z (S) $3978
More inspections in this industry (NAICS 237110)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344356761.