Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FIRESTONE COMPLETE AUTO CARE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FIRESTONE COMPLETE AUTO CARE in 13027 VANDERGRIFT BLVD, CAMP PENDLETON, CA 92055 (NAICS 811191). OSHA activity number 344359138.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Firestone Complete Auto Care — free Get an email when a new federal OSHA severe-injury report for Firestone Complete Auto Care is published. One employer, no account, unsubscribe in one click.
Site address
13027 VANDERGRIFT BLVD
City
CAMP PENDLETON
State
CA
ZIP
92055
Mailing
13027 VANDERGRIFT BLVD, CAMP PENDLETON, CA 92055
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811191
Employees
11
Ownership type
A

17 citations on file for this inspection.

1910.29 F01 II A

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 3, 2020
Abate by
Feb 21, 2020
Penalty
Initial $10,229 · Current $5,115 Reduced
29 CFR 1910.29(f)(1)(ii)(A):  The height of stair rail systems installed before January 17, 2017 was less than 30 inches from the leading edge of the stair tread to the top surface of the top rail:  Building 1327, Retail Store, Stairwell access to the 2nd floor:  Employees were using the stairs to access the 2nd floor for tires stored in the South room.  Employees use the stairs up to 20 times per day in conjunction with their normal duties. The height of the stair rail system measured from the leading edge of the stair tread to the top surface of the top rail was measured to 29 inches. Employees were exposed to trip/miss-step and falls.
Recent events (3)
  • — F (S) $5115
  • — C (S) $10229
  • — Z (S) $10229

1910.29 F02

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 3, 2020
Abate by
Feb 21, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.29(f)(2): Finger clearance.  The minimum clearance between handrails and any other object was not 2.25 inches:   Building 1327, Retail Store, Stairwell access to the 2nd floor:  Employees were accessing stairs that had a single square iron top rail to retrieve tires that were stored on the 2nd floor in conjunction with their normal duties.  The top rail was installed flush with the wall and did not allow employees to fully grip the railing.  Employees were exposed to trip/miss-step and falls.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.29 F03

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 3, 2020
Abate by
Feb 21, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.29(f)(3): Surfaces.  Handrails and stair rail systems were not smooth-surfaced to protect employees from injury, such as punctures or lacerations, and to prevent catching or snagging of clothing:   Building 1327, Retail Store, Stairwell access to the 2nd floor:  Employees were accessing stairs that had a single square iron top rail to retrieve tires that were stored on the 2nd floor in conjunction with their normal duties.  The railing had sharp corner areas at the entry points of the stairs that had the ability to catch clothing and employees.  Employees were exposed to punctures, lacerations and falls.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.29 F04

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 3, 2020
Abate by
Feb 21, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.29(f)(4): Opening in the stair rail system exceeded 19 inches at its least dimension:   Building 1327, Retail Store, Stairwell access to the 2nd floor:  Employees were using the stairs to access the 2nd floor for tires stored in the South room.  Employees use the stairs up to 20 times per day in conjunction with their normal duties. The stair rail system was not installed with a midrail and/or baluster to avoid an opening of greater than 19 inches.  Employees were exposed to trip/miss-step and falls.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.29 F05

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 3, 2020
Abate by
Feb 21, 2020
Penalty
Initial $0 · Current $0
1910.29(f)(5)  Handhold. Handrails did not have the shape and dimension necessary so that employees can grasp the handrail firmly:    Building 1327, Retail Store, Stairwell access to the 2nd floor:  Employees were accessing stairs that had a single square iron top rail to retrieve tires that were stored on the 2nd floor in conjunction with their normal duties.  The stairwell did not have grippable stair rail system and handrail.  Employees were exposed to a trip/miss-step and fall.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.22 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 3, 2020
Abate by
Jan 30, 2020
Penalty
Initial $10,229 · Current $5,115 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces were not kept in a clean, orderly, and sanitary condition.   a) Building 1327, 2nd Floor North Storage room: Employees had to step up on file storage boxes to get specific tires due to accumulation of file boxes that were stored on the ground and upper wall shelving.  The large amount of paper file storage boxes in this area exposed employees to fire hazards, trips, and falls.    b) Building 13026, Mechanical Shop: Employees were exposed to trip hazards due to Klutch Retractable Heavy Duty Air Hoses were found lying on the ground at the center and South center bay areas.
Recent events (3)
  • — F (S) $5115
  • — C (S) $10229
  • — Z (S) $10229

1910.22 D01

Serious Gravity 5 2 instances 4 exposed
Issued
Jan 3, 2020
Abate by
Jan 30, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): The employer did not ensure that walking-working surfaces were inspected, regularly and as necessary, and maintained in a safe condition.   a) Building 1327, 2nd Floor North Storage room: Employees had to step up on file storage boxes to get specific tires due to accumulation of file boxes that were stored on the ground and upper wall shelving.  The large amount of paper file storage boxes in this area exposed employees to fire hazards, trips, and falls.  b) Building 13026, Mechanical Shop: Employees were exposed to trip hazards due to Klutch Retractable Heavy Duty Air Hoses were found lying on the ground at the center and south center bay areas.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.29 B02 I

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 3, 2020
Abate by
Feb 21, 2020
Penalty
Initial $11,934 · Current $11,934
29 CFR 1910.29(b)(2)(i): Midrails were not installed at a height midway between the top edge of the guardrail system and the walking-working surface:   Building 1327, 2nd floor, Vertical Cleated Belt Conveyor:  The elevator shaft opening to the conveyor a midrail was not installed. Employees were exposed to a 10 foot fall hazard.
Recent events (3)
  • — F (S) $11934
  • — C (S) $11934
  • — Z (S) $11934

1910.36 G02

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 3, 2020
Abate by
Feb 21, 2020
Penalty
Initial $8,525 · Current $5,115 Reduced
29 CFR 1910.36(g)(2): Exit access was not at least 28 inches wide at all points. Aisles were not of sufficient width to allow the safe evacuation of all the people who work on the floor served by the aisle:  Building 1327, Retail Store, storage room for tires:  The far North isle was measured to be 19 inches in width.  Employees were exposed to a narrow escape route and fire hazard.
Recent events (3)
  • — F (S) $5115
  • — C (S) $8525
  • — Z (S) $8525

1910.157 E01

Serious Gravity 1 2 instances 4 exposed
Issued
Jan 3, 2020
Abate by
Feb 21, 2020
Penalty
Initial $5,115 · Current $5,115
29 CFR 1910.157(e)(1): The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace.   a) Building 13026, Maintenance shop, Center Bay Area:  The fire extinguishers had no inspection seal and the inspection tag was not updated as being inspected.   b) Building 13027, exterior of the retail store:  The fire extinguisher had no inspection tag indicating inspections were completed.
Recent events (3)
  • — F (S) $5115
  • — C (S) $5115
  • — Z (S) $5115

1910.303 B02

Serious Gravity 1 2 instances 4 exposed
Issued
Jan 3, 2020
Abate by
Jan 30, 2020
Penalty
Initial $5,115 · Current $5,115
29 CFR 1910.303(b): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling and unused opening in electrical cabinets were not effectively closed to provide substantially equivalent protection to the equipment:  a) Building 13206, North office: The fridge used to store food and beverages was plugged into a yellow extension cord then into wall outlet. Employees were exposed to electrical hazards.  b) Building 13026, North Bay Area: The power strip used to charge batteries and tools was plugged into an orange extension cord then into the wall outlet. Employees were exposed to electrical hazards.  c) Building 1327, 2nd Floor Tire Storage Room: The electrical switchbox attached to the HVAC unit on the North wall had a missing knock out on the metal housing. Employees pulled tires off racks in this aisle and passed by the electrical hazards to exit the narrow aisle way. Employees were exposed to electrical hazards.
Recent events (3)
  • — F (S) $5115
  • — C (S) $5115
  • — Z (S) $5115

1910.305 B01 I

Serious Gravity 5 3 instances 4 exposed
Issued
Jan 3, 2020
Abate by
Feb 21, 2020
Penalty
Initial $10,229 · Current $6,819 Reduced
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors enter were not effectively closed.   Building 1327, North Storage room:  The HVAC unit on the North wall had round sharp cutouts from the aluminum housing which had electrical wiring passing through and was not effectively closed.  Employees were exposed to electrical hazards.
Recent events (3)
  • — F (S) $6819
  • — C (S) $10229
  • — Z (S) $10229

1910.303 C03 I

Serious Gravity 5 2 instances 4 exposed
Issued
Jan 3, 2020
Abate by
Feb 21, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(c)(3)(i): Conductors were not spliced or joined with splicing devices identified for the use or by brazing, welding, or soldering with a fusible metal or alloy.  All splices and joints and the free ends of conductors were not covered with an insulation equivalent to that of the conductors or with an insulating device identified for the purpose.   Building 1327, 2nd Floor Tire Storage Room:  The HVAC unit on the North wall had exposed wiring spliced together with black tape. Employees pulled tires off racks in this aisle and passed by the electrical hazards to exit the narrow aisle way. Employees were exposed to electrical hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 2 instances 4 exposed
Issued
Jan 3, 2020
Abate by
Feb 21, 2020
Penalty
Initial $6,819 · Current $5,115 Reduced
29 CFR 1910.305: Flexible cord and cables were not connected to devices and fittings so that strain relief was provided that will prevent pull from being directly transmitted to joints or terminal screws and boxes were not closed by suitable covers securely fastened in place.  a) Building 13026, Maintenance Shop: The Hubbell Wiring Device-Kellems Ext. Cord Reel did not have strain relief and the rubber sheathing was pulled away from the coated electrical copper wire plug housing point. Employees were exposed to electrical hazards.  b) Building 13026, Maintenance Shop: The Tire Balancing Machine did not have strain relief and the rubber sheathing was pulled away from the coated electrical copper wire plug housing point. Employees were exposed to electrical hazards.  c) Building 13026, Maintenance Shop, Center Aisle way: The electrical transfer box cover was open and not secured to the box housingshowing exposed wiring. Employees continuously work in this area servicing vehicles and continuously throughout the day pass the electrical fixtures. Employees are exposed to electrical hazards.
Recent events (3)
  • — F (S) $5115
  • — C (S) $6819
  • — Z (S) $6819

1910.303 B07 I

Deleted Serious Gravity 1 1 instance 4 exposed
Issued
Jan 3, 2020
Abate by
Feb 21, 2020
Penalty
Initial $5,115 · Current $0 Reduced
29 CFR 1910.303(b)(7)(i): Unused opening in electrical cabinets were not effectively closed provide substantially equivalent protection to the equipment:  Building 1327, 2nd Floor Tire Storage Room:  The electrical switchbox attached to the HVAC unit on the North wall had a missing knock out on the metal housing.   Employees pulled tires off racks in this aisle and passed by the electrical hazards to exit the narrow aisle way. Employees were exposed to electrical hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $5115
  • — Z (S) $5115

1910.305 B03 II

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Jan 3, 2020
Abate by
Feb 21, 2020
Penalty
Initial $6,819 · Current $0 Reduced
29 CFR 1910.305(b)(3)(ii): Boxes were not closed by suitable covers securely fastened in place.  Building 13026, Maintenance Shop, Center Aisle way:  The electrical transfer box cover was open and not secured to the box housing showing exposed wiring. Employees continuously work in this area servicing vehicles and continuously throughout the day pass the electrical fixture. Employees are exposed to electrical hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $6819
  • — Z (S) $6819

1910.23 C03

Deleted Other-than-serious 1 instance 4 exposed
Issued
Jan 3, 2020
Abate by
Jan 30, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.23(c)(3): Ladders are not to be loaded beyond the maximum intended load. (weight of the worker, tools and equipment)   Building 13026, Maintenance bay, Battery room: The A frame ladder observed during inspection did not have any manufacture data listed for load limits for employees to identify during inspection and use of ladder.  Employees are exposed to fall hazards.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0