Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R.J. BIANCHINI JR. CONCRETE AND BUILDING RESORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of R.J. BIANCHINI JR. CONCRETE AND BUILDING RESORATION in 521 SNYDER AVENUE, PHILADELPHIA, PA 19148 (NAICS 238140). OSHA activity number 344359401.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R.J. Bianchini JR. Concrete and Building Resoration — free Get an email when a new federal OSHA severe-injury report for R.J. Bianchini JR. Concrete and Building Resoration is published. One employer, no account, unsubscribe in one click.
Site address
521 SNYDER AVENUE
City
PHILADELPHIA
State
PA
ZIP
19148
Mailing
1045 HORSHAM RD, AMBLER, PA 19002
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 30, 2020
Abate by
Apr 23, 2020
Penalty
Initial $4,048 · Current $4,048
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)  a) Jobsite - The employer failed to ensure that all scaffold working platforms were fully decked or planked exposing employees to fall hazards of approximately twenty (20) feet. Observed on or about 02 OCT 2019.
Recent events (1)
  • — Z (S) $4048

1926.451 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 30, 2020
Abate by
Apr 23, 2020
Penalty
Initial $4,048 · Current $4,048
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph.  a) Jobsite - The employer failed to ensure that the scaffold was guyed, tied, or braced when the scaffold was erected with a base to height ratio of 6.3 to 1 exposing employees to possible scaffold collapse. Observed on or about 02 OCT 2019.
Recent events (1)
  • — Z (S) $4048

1926.451 G01 VII

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 30, 2020
Abate by
Apr 23, 2020
Penalty
Initial $4,048 · Current $4,048
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  a) Jobsite - The employer did not ensure that all employees were guarded by endrails when working from a tubular welded scaffold exposing employees to fall hazards of approximately twenty (20) feet.  Observed on or about 02 OCT 2019.
Recent events (1)
  • — Z (S) $4048

1926.451 F06

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 30, 2020
Abate by
Apr 23, 2020
Penalty
Initial $4,048 · Current $4,048
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).  a) Jobsite - The employer failed to ensure that scaffolds erected around a service line and service drop were distanced at least three (3) feet from all conductive material of the tubular welded scaffold exposing employees to electrical hazards. Observed on or about 02 OCT 2019.
Recent events (1)
  • — Z (S) $4048

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344359401.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.