HARRISBURG, PA —
OSHA Inspection: CMC ROOFING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CMC ROOFING, LLC in 830 SIR THOMAS COURT, HARRISBURG, PA 17108 (NAICS 238160). OSHA activity number 344362637.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CMC ROOFING, LLC
- Site address
- 830 SIR THOMAS COURT
- City
- HARRISBURG
- State
- PA
- ZIP
- 17108
- Mailing
- 721 GINGRICH LANE, DAUPHIN, PA 17018
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1903.19 C01
- Issued
- Dec 19, 2019
- Abate by
- Jan 23, 2020
- Penalty
- Initial $319 · Current $319
General-duty citation text
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: a) Location - Facility On or about December 12, 2019, the employer did not certify that the violations had been corrected.
Recent events (1)
- — Z (O) $319
1926.102 A01
- Issued
- Oct 28, 2019
- Abate by
- Nov 22, 2019
- Penalty
- Initial $2,842 · Current $2,131 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents: a) Roof - On or about October 8, 2019, an employee was observed operating a pneumatic nail gun to secure shingles to the roof of a building and was not provided eye protection, exposed to ricochet nails and flying debris. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2131
- — Z (S) $2842
1926.501 B11
- Issued
- Oct 28, 2019
- Abate by
- Nov 22, 2019
- Penalty
- Initial $2,842 · Current $2,131 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems or personal fall arrest systems: a) Roof - On or about October 8, 2019, and times prior thereto, employees removing and installing roofing materials were permitted to work at elevated heights on a 6:12 sloped roof, as far as approximately 8 feet above ground level, and were not protected from falling. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2131
- — Z (S) $2842
1926.503 A01
- Issued
- Oct 28, 2019
- Abate by
- Dec 2, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): A training program was not provided to each employee who might be exposed to fall hazards, to enable that employee to recognize the hazards of falling, and be trained in the procedures to be followed to minimize these hazards: a) Roof - On or about October 8, 2019, and times prior thereto, employees were not trained in appropriate fall protection methods to avoid hazards associated with elevated work areas. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344362637.