Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EASTERN CONSOLIDATION AND DISTRIBUTION SERVICES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EASTERN CONSOLIDATION AND DISTRIBUTION SERVICES, INC. in 2244 GETTYSBURG ROAD, CAMP HILL, PA 17011 (NAICS 484122). OSHA activity number 344364971.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Eastern Consolidation and Distribution Services, INC. — free Get an email when a new federal OSHA severe-injury report for Eastern Consolidation and Distribution Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2244 GETTYSBURG ROAD
City
CAMP HILL
State
PA
ZIP
17011
Mailing
405 STERLING STREET, CAMP HILL, PA 17011
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484122
Employees
53
Ownership type
A

4 citations on file for this inspection.

1910.151 C

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 22, 2019
Abate by
Dec 27, 2019
Penalty
Initial $5,304 · Current $3,978 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  a) Cleaning Chemicals - Employees mixing and using corrosive chemicals such as Multiquat No. 455 and Liquid Fury No. 270 were exposed to serious eye and skin damage from not having an eyewash and shower in the area, on or about October 3rd, 2019.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $3978
  • — Z (S) $5304

1910.303 B07 I

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 22, 2019
Penalty
Initial $3,978 · Current $2,984 Reduced
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment:  a) Service Panel For Wash Bay - The employees accessing a service panel for the wash bay to turn on and off lights were exposed to electrical hazards from three open bolt holes on panel cover, on or about October 3rd, 2019.  No abatement certification or documentation required.
Recent events (2)
  • — I (S) $2983.5
  • — Z (S) $3978

1910.157 G01

Other-than-serious 1 instance 8 exposed
Issued
Nov 22, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting:  a) 2244 Gettysburg Road - The employees expected to use fire extinguishers for incipient stage firefighting were not trained in the principles of fire extinguisher use and the hazards involved with incipient stage firefighting, on or about October 3rd, 2019.   Note:  Applies where all employees are expected to fight fires.  No abatement certification or documentation required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 2 instances 2 exposed
Issued
Nov 22, 2019
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) Office Service Panel - The employer did not ensure that space in front of the service panel was kept clear.  Items such as a shovel and a wet dry vacuum were stored in the working space in front of the panel, on or about October 3rd, 2019.  b) Wash Bay Service Panel - The employer did not ensure that space in front of the service panel was kept clear. Items such as a 55 gal plastic barrel of water were stored in the working space in front of the panel, on or about October 3rd, 2019.  No abatement certification or documentation required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Eastern Consolidation and Distribution Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344364971.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.