CHICAGO, IL —
OSHA Inspection: MAUSER PACKAGING SOLUTIONS DBA MEYER STEEL DRUM, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MAUSER PACKAGING SOLUTIONS DBA MEYER STEEL DRUM, INC. in 3201 S. MILLARD AVENUE, CHICAGO, IL 60623 (NAICS 332431). OSHA activity number 344366919.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 3201 S. MILLARD AVENUE
- City
- CHICAGO
- State
- IL
- ZIP
- 60623
- Mailing
- 3201 S. MILLARD AVENUE, CHICAGO, IL 60623
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332431
- Employees
- 119
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 II
- Issued
- Dec 3, 2019
- Abate by
- Dec 30, 2019
- Penalty
- Initial $11,366 · Current $11,366
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a) On or about October 1, 2019, employees were required to service and/or maintain the Out-of-the-Primer-Booth Up-ender. The Out-of-the-Primer-Booth Up-ender had three or more sources of energy (electrical (480 volt)), compressed air, and gravity. The employer's written lockout program and energy control procedures did not address venting the compressed air lines, how to control gravity as a source of energy and did not include the following: i) A specific statement of the intended use of the procedure as required by 29 CFR 1910.147(c)(4)(ii)(A). ii) Specific procedural steps to for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy as required by 29 CFR 1910.147(c)(4)(ii)(B). iii) Specific procedural steps to for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them as required by 29 CFR 1910.147(c)(4)(ii)(C). iv) Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices and other energy control measures as required by 29 CFR 1910.147(c)(4)(ii)(D).
Recent events (1)
- — Z (S) $11366
1910.147 D
- Issued
- Dec 3, 2019
- Abate by
- Dec 30, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1) through (d)(6): a) On or about October 1, 2019, at the end of the Drum Primer Booth, employees were exposed to machine hazards associated with moving parts when required to service and/or maintain the Drum Upender. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (1)
- — Z (S) $0
More inspections at Mauser Packaging Solutions DBA Meyer Steel Drum, INC.
View Mauser Packaging Solutions DBA Meyer Steel Drum, INC.'s full OSHA safety record →