FALCONER, NY —
OSHA Inspection: ELLISON BRONZE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ELLISON BRONZE, INC. in 125 WEST MAIN STREET, FALCONER, NY 14733 (NAICS 332321). OSHA activity number 344370812.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ELLISON BRONZE, INC.
- Site address
- 125 WEST MAIN STREET
- City
- FALCONER
- State
- NY
- ZIP
- 14733
- Mailing
- 125 WEST MAIN STREET, FALCONER, NY 14733
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- Employees
- 56
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C05 II B
- Issued
- Oct 23, 2019
- Abate by
- Nov 15, 2019
- Penalty
- Initial $2,984 · Current $2,238 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(B): Lockout and tagout devices were not standardized within the facility in at least one of the following criteria: color; shape; or size: a) On or about 10/17/2019 throughout establishment; where locks used for controlling hazardous energy were not standardized. Multiple types, sizes and colors of locks were observed (including red MASTER locks and silver ABUS locks). ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2238
- — Z (S) $2984
1910.37 B05
- Issued
- Oct 23, 2019
- Abate by
- Nov 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): a) On or about 10/17/2019 in the painting area; where a door to the electrical room was not identified. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 L04 III
- Issued
- Oct 23, 2019
- Abate by
- Nov 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) On or about 10/09/2019 throughout production; where many of the powered industrial vehicle operators were last evaluated and certified in March of 2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0