CINCINNATI, OH —
OSHA Inspection: ALL AMERICAN BUILDING CO., INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ALL AMERICAN BUILDING CO., INC. in 4043 MCMANN RD., CINCINNATI, OH 45245 (NAICS 238120). OSHA activity number 344381116.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALL AMERICAN BUILDING CO., INC.
- Site address
- 4043 MCMANN RD.
- City
- CINCINNATI
- State
- OH
- ZIP
- 45245
- Mailing
- 5861 CLOUGH PIKE, CINCINNATI, OH 45244
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 5
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.20 B02
- Issued
- Feb 27, 2020
- Abate by
- Apr 14, 2020
- Penalty
- Initial $4,048 · Current $3,000 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs to provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers. On or about October 11, 2019 there was no frequent and regular inspection program being maintained in use by a competent person to ensure the job site materials and equipment such as roof deck steel erection activities associated with metal standing seam roof decking installation fall protection devices and or systems were being utilized or maintained in a safe condition exposing employees to fall potentials ranging from 23 feet to in excess of 31 feet.
Recent events (2)
- — I (S) $3000
- — Z (S) $4048
1926.502 D11
- Issued
- Feb 27, 2020
- Abate by
- Mar 4, 2020
- Penalty
- Initial $4,048 · Current $0 Reduced
General-duty citation text
29 CFR 1926.502(d)(11): Lifelines shall be protected against being cut or abraded. On or about October 11, 2019 located on the roof deck, steel erection activities associated with metal standing seam roof decking installation was being performed by employee(s) on which the employees personal fall arrest systems lifeline were not protected or softened from abrasion of the leading edge and perimeter exterior eave edge metal roof deck sheeting exposing employees to fall potentials ranging from 23 feet to in excess of 31 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $4048
1926.502 D16 III
- Issued
- Feb 27, 2020
- Abate by
- Mar 4, 2020
- Penalty
- Initial $4,048 · Current $3,500 Reduced
General-duty citation text
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, shall be rigged such that an employee can neither free fall more than 6 feet (1.8 m), nor contact any lower level; On or about October 11, 2019 located on the roof deck, steel erection activities associated with metal standing seam roof decking installation was being performed by employee(s) on which the employees personal fall arrest systems lifeline being used exposed employees to perimeter exterior roof deck eave fall potentials in excess of 6 feet or striking surfaces below.
Recent events (2)
- — I (S) $3500
- — Z (S) $4048
1926.760 A01
- Issued
- Feb 27, 2020
- Abate by
- Mar 4, 2020
- Penalty
- Initial $4,048 · Current $0 Reduced
General-duty citation text
29 CFR 1926.760(a)(1): Except as provided by paragraph (a)(3) of this section, each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level shall be protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems. On or about October 11, 2019 located on the roof deck, steel erection activities associated with metal standing seam roof decking installation was being performed by employee(s) without the use of conventional fall protection exposing employees to fall potentials ranging from 23 feet to in excess of 31 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $4048
1926.761 B
- Issued
- Feb 27, 2020
- Abate by
- Apr 14, 2020
- Penalty
- Initial $4,048 · Current $0 Reduced
General-duty citation text
29 CFR 1926.761(b): The employer shall train each employee exposed to a fall hazard in accordance with the requirements of this section. The employer shall institute a training program and ensure employee participation in the program. On or about October 11, 2019 and prior to that time located on the roof deck, steel erection activities associated with metal standing seam roof decking installation was being performed by employees without the use of conventional fall protection, lifelines not protected from abrasion and fall protection systems which would allow a freefall in excess of six feet or striking surface(s) below exposing employees to fall potentials ranging from 23 feet to in excess of 31 feet who were not trained or knowledgeable of the fall protection regulation requirements of Subpart R or procedures to minimize those hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $4048
More inspections at ALL American Building CO., INC.
View ALL American Building CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344381116.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.