OSHA Inspection: ALL AMERICAN BUILDING CO., INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ALL AMERICAN BUILDING CO., INC. in 4043 MCMANN RD., CINCINNATI, OH 45245 (NAICS 238120). OSHA activity number 344381116.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ALL American Building CO., INC. — free Get an email when a new federal OSHA severe-injury report for ALL American Building CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
4043 MCMANN RD.
City
CINCINNATI
State
OH
ZIP
45245
Mailing
5861 CLOUGH PIKE, CINCINNATI, OH 45244
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
5
Ownership type
A

5 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 27, 2020
Abate by
Apr 14, 2020
Penalty
Initial $4,048 · Current $3,000 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs to provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.     On or about October 11, 2019 there was no frequent and regular inspection program being maintained in use by a competent person to ensure the job site materials and equipment such as roof deck steel erection activities associated with metal standing seam roof decking installation fall protection devices and or systems were being utilized or maintained in a safe condition exposing employees to fall potentials ranging from 23 feet to in excess of 31 feet.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4048

1926.502 D11

Serious Gravity 10 1 instance 4 exposed
Issued
Feb 27, 2020
Abate by
Mar 4, 2020
Penalty
Initial $4,048 · Current $0 Reduced
29 CFR 1926.502(d)(11): Lifelines shall be protected against being cut or abraded.       On or about October 11, 2019 located on the roof deck, steel erection activities associated with metal standing seam roof decking installation was being performed by employee(s) on which the employees personal fall arrest systems lifeline were not protected or softened from abrasion of the leading edge and perimeter exterior eave edge metal roof deck sheeting exposing employees to fall potentials ranging from 23 feet to in excess of 31 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4048

1926.502 D16 III

Serious Gravity 10 2 instances 2 exposed
Issued
Feb 27, 2020
Abate by
Mar 4, 2020
Penalty
Initial $4,048 · Current $3,500 Reduced
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, shall be rigged such that an employee can neither free fall more than 6 feet (1.8 m), nor contact any lower level;    On or about October 11, 2019 located on the roof deck, steel erection activities associated with metal standing seam roof decking installation was being performed by employee(s) on which the employees personal fall arrest systems lifeline being used exposed employees to perimeter exterior roof deck eave fall potentials in excess of 6 feet or striking surfaces below.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $4048

1926.760 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 27, 2020
Abate by
Mar 4, 2020
Penalty
Initial $4,048 · Current $0 Reduced
29 CFR 1926.760(a)(1): Except as provided by paragraph (a)(3) of this section, each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level shall be protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems.     On or about October 11, 2019 located on the roof deck, steel erection activities associated with metal standing seam roof decking installation was being performed by employee(s) without the use of conventional fall protection exposing employees to fall potentials ranging from 23 feet to in excess of 31 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4048

1926.761 B

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Feb 27, 2020
Abate by
Apr 14, 2020
Penalty
Initial $4,048 · Current $0 Reduced
29 CFR 1926.761(b): The employer shall train each employee exposed to a fall hazard in accordance with the requirements of this section. The employer shall institute a training program and ensure employee participation in the program.   On or about October 11, 2019 and prior to that time located on the roof deck, steel erection activities associated with metal standing seam roof decking installation was being performed by employees without the use of conventional fall protection, lifelines not protected from abrasion and fall protection systems which would allow a freefall in excess of six feet or striking surface(s) below exposing employees to fall potentials ranging from 23 feet to in excess of 31 feet who were not trained or knowledgeable of the fall protection regulation requirements of Subpart R or procedures to minimize those hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4048

View ALL American Building CO., INC.'s full OSHA safety record →