WASHINGTON, DC —
OSHA Inspection: G & K MASONRY LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of G & K MASONRY LLC in 4834 QUEBEC STREET NW, WASHINGTON, DC 20016 (NAICS 238140). OSHA activity number 344381306.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- G & K MASONRY LLC
- Site address
- 4834 QUEBEC STREET NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20016
- Mailing
- 8174 PEAKWOOD CRT. APT. 2, MANASSAS, VA 20111
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 6
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.100 A
- Issued
- Apr 15, 2020
- Abate by
- Apr 22, 2020
- Penalty
- Initial $2,949 · Current $2,949
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about October 15, 2019; front of residential site; employees working on the ground level near the scaffold system were not wearing hard hats to protect them from falling objects such as but not limited to tools or materials used in the masonry process. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $2949
1926.451 B01
- Issued
- Apr 15, 2020
- Abate by
- Apr 22, 2020
- Penalty
- Initial $4,048 · Current $4,048
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) On or about October 15, 2019; front of residential site; the working platform of the east-side scaffold had 2 planks missing, exposing the employees to an estimated 13-foot fall hazard while conducting masonry work. b) On or about October 15, 2019; front of residential site; the working platform of the north-side scaffold had 1 plank missing, exposing the employees to an estimated 17-foot fall hazard while conducting masonry work. c) On or about October 15, 2019; front of residential site; the working platform of the west-side scaffold had 1 plank missing, exposing the employees to an estimated 17-foot fall hazard while conducting masonry work. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $4048
1926.451 B05 I
- Issued
- Apr 15, 2020
- Abate by
- Apr 22, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(5)(i): The end of a platform 10 feet or less in length, extended over its support more than 12 inches: a) On or about October 15, 2019; front of residential site; the two planks on the outrigger of the west-side scaffold system were extended an estimated 24-inches beyond the support frame exposing the employees to a fall hazard of approximately 17-feet. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $0
1926.451 C01 II
- Issued
- Apr 15, 2020
- Abate by
- Apr 22, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(1)(ii): Guys, ties, and/or braces were not installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and repeated vertically at locations of horizontal members every 20 feet (56.1 m) or less thereafter for scaffolds 3 feet ((0.91 m) wide or less, and every 26 feet (7.9 m) or less therafter for scaffolds greater than 3 feet (0.91m) wide: a) On or about October 15, 2019; front area of the residential building; employees were observed working on a 4 tier scaffold system, which at its highest point was approximately 24-foot high and was not secured to prevent from tipping. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $0
1926.451 E01
- Issued
- Apr 15, 2020
- Abate by
- Apr 22, 2020
- Penalty
- Initial $4,048 · Current $4,048
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) On or about October 15, 2019; front area of the residential building; the employees were observed using the scaffold system frame and cross-braces to access the working platforms of the scaffold system exposing the employees to a fall hazard of approximately 13-feet to 17-feet. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $4048
1926.451 G01 VII
- Issued
- Apr 15, 2020
- Abate by
- Apr 22, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) On or about October 15, 2019; front of residential project; employees conducting masonry work were exposed to a fall hazard of approximately 13-feet to 17-feet while using two unguarded cross-overs which united the three sections of scaffolds. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $0
1926.451 G04 I
- Issued
- Apr 15, 2020
- Abate by
- Apr 22, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: a) On or about October 15, 2019; front of residential project; the three working platforms of the scaffold systems were not equipped with guardrail systems at any of the ends, exposing employees to a fall hazard of approximately 13-feet to 17-feet while conducting masonry work. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $0
1926.451 G04 IV
- Issued
- Apr 15, 2020
- Abate by
- Apr 22, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4)(iv): Midrails were not installed at a height approximately midway between the top edge of the guardrail system and the platform surface: a) On or about October 15, 2019; front of residential site; the employer had not installed mid-rails along any of the three working platforms, exposing employees to a fall hazard of approximately 13-feet to 17-feet while hoisting materials to the platforms. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $0
1926.451 H02 II
- Issued
- Apr 15, 2020
- Abate by
- Apr 22, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: a) On or about October 15, 2019; front of residential site; toe boards were not installed on any of the three working platforms of the scaffold system to prevent masonry tools or materials from falling and striking the employee working on the ground below the scaffolds. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 238140)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344381306.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.