Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NIKSIC AIR CONDITIONING AND HEATING LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of NIKSIC AIR CONDITIONING AND HEATING LLC in 50 RICHMOND CENTER BOULEVARD, SAINT PETERS, MO 63376 (NAICS 238990). OSHA activity number 344384458.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Niksic AIR Conditioning and Heating LLC — free Get an email when a new federal OSHA severe-injury report for Niksic AIR Conditioning and Heating LLC is published. One employer, no account, unsubscribe in one click.
Site address
50 RICHMOND CENTER BOULEVARD
City
SAINT PETERS
State
MO
ZIP
63376
Mailing
3419 GRATIOT STREET, SAINT LOUIS, MO 63103
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
30
Ownership type
A

4 citations on file for this inspection.

1926.651 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 13, 2020
Penalty
Initial $9,282 · Current $4,641 Reduced
29 CFR 1926.651(c)(2):   A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:   On 10/17/2019, employees of Niksic Air Conditioning & Heating LLC were installing 12 inch pipe at a commercial building 50 Richmond Center Blvd., Saint Peters, Missouri.  The employer did not provide or ensure that a safe means of egress was located in the excavation.  The trench used by employees measured approximately 34 feet in length, 9 feet wide and 6.5 feet deep.
Recent events (2)
  • — I (S) $4641
  • — Z (S) $9282

1926.651 J02

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 13, 2020
Penalty
Initial $3,978 · Current $1,989 Reduced
29 CFR 1926.651(j)(2):  Protection was not provided by placing and keeping such materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary:  On 10/17/2019, employees of Niksic Air Conditioning & Heating LLC were installing 12 inch pipe at a commercial building 50 Richmond Center Blvd., Saint Peters, Missouri.  Employees were exposed to struck by hazards while working below excavated rock and soil piled on the edge of the excavation.
Recent events (2)
  • — I (S) $1989
  • — Z (S) $3978

1926.651 K01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 13, 2020
Abate by
Feb 7, 2020
Penalty
Initial $7,956 · Current $3,978 Reduced
29 CFR 1926.651(k)(1):  Daily inspections of excavations, the adjacent areas, and protective systems was not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions. An inspection was not conducted by the competent person prior to the start of work and as needed throughout the shift:  On 10/17/2019, employees of Niksic Air Conditioning & Heating LLC were installing 12 inch pipe at a commercial building located at 50 Richmond Center Blvd., Saint Peters, Missouri.  The employer did not ensure a competent person inspected the excavation and surrounding areas to identify any potential hazards prior to the start of work.
Recent events (2)
  • — I (S) $3978
  • — Z (S) $7956

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 13, 2020
Penalty
Initial $9,282 · Current $4,641 Reduced
29 CFR 1926.652(a)(1):  Each employee in an excavation shall be protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section:  On 10/17/2019, employees of Niksic Air Conditioning & Heating LLC were installing 12 inch pipe at a commercial building located at 50 Richmond Center Blvd., Saint Peters, Missouri.  The employer did not provide or require the use of benching, sloping, shoring or other means to ensure that employees working in excavations were protected from engulfment hazards. The trench measured approximately 6.5 feet in depth, 9 feet in width and 34 feet in length.
Recent events (2)
  • — I (S) $4641
  • — Z (S) $9282

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344384458.