ROSLINDALE, MA —
OSHA Inspection: KINETIC SYSTEMS INCORPORATED
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of KINETIC SYSTEMS INCORPORATED in 20 ARBORETUM ROAD, ROSLINDALE, MA 02131 (NAICS 332999). OSHA activity number 344386685.
Where did this inspection happen?
- Establishment
- KINETIC SYSTEMS INCORPORATED
- Site address
- 20 ARBORETUM ROAD
- City
- ROSLINDALE
- State
- MA
- ZIP
- 02131
- Mailing
- 20 ARBORETUM ROAD, ROSLINDALE, MA 02131
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 23
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $4546.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: CNC Milling Machine Section: Lockout tagout procedures were not used while employees were leveling a table prior to milling three holes.
Recent events (2)
- — I (S) $1000
- — Z (S) $4546
1910.147 C07 I A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: CNC Milling Machine Section: The operator of the Awea Mechanitronic CNC Milling Machine was not trained on lockout tagout procedures for setting up a vibration table while a helper is inside the machine.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C07 I B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: CNC Milling Machine Section: The employer did not instruct an employee helping the operator of the Awea Mechantronic CNC Milling Machine, positioning a vibration table for drilling holes, on the purpose of lockout tagout procedures and the methods used to lockout the machine.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $3789.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: CNC Milling Section: 1) The sliding door guard of the Awea Mechantronic CNC Milling Machine was not interlocked with the drive mechanism to prevent the cutting tool from spinning while the cover was opened. 2) Access to the screw conveyors to remove the chips at the Awea Mechantronic CNC Milling Machine was not blocked off or alternatively the screw conveyors were not equipped with grate covers.
Recent events (2)
- — I (S) $1000
- — Z (S) $3789
More inspections at KINETIC SYSTEMS INCORPORATED
BOSTON, MA—2011-01-24 00:00:00
KINETIC SYSTEMS INCORPORATED
BOSTON, MA—2006-09-25 00:00:00
KINETIC SYSTEMS INCORPORATED
BOSTON, MA—2003-03-06 00:00:00
KINETIC SYSTEMS INCORPORATED
View KINETIC SYSTEMS INCORPORATED's full OSHA safety record →
More inspections in this industry (NAICS 332999)
SMITHFIELD, UT—2026-07-16
METAL VISION INC.
MINNEAPOLIS, MN—2026-07-15
111597 - CHANDLER INDUSTRIES INC - BLAINE DIVISION
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
HUNTINGDON VALLEY, PA—2026-07-09
METAL ALLIANCE, INC.
More inspections in MA
BELLINGHAM, MA—2026-07-16
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WESTFIELD, MA—2026-07-15
BOISE CASCADE BUILDING MATERIALS DISTRIBUTION, L.L.C.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
FALL RIVER, MA—2026-07-15
CRESCO LABS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344386685.