Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FACILITY SOLUTIONS GROUP

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of FACILITY SOLUTIONS GROUP in 5500 FRISCO SQUARE BLVD., FRISCO, TX 75034 (NAICS 238210). OSHA activity number 344388319.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Facility Solutions Group — free Get an email when a new federal OSHA severe-injury report for Facility Solutions Group is published. One employer, no account, unsubscribe in one click.
Site address
5500 FRISCO SQUARE BLVD.
City
FRISCO
State
TX
ZIP
75034
Mailing
2525 WALNUT HILL LANE SUITE 100, DALLAS, TX 75229
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.403 D01

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Dec 11, 2019
Abate by
Jan 8, 2020
Penalty
Initial $13,260 · Current $0 Reduced
29 CFR 1926.403(d)(1): Electric equipment was not firmly secured to the surface on which it was mounted:  (a) On or about October 17, 2019; temporary electrical wiring located near the base of the tower crane included a permanent metal junction box that was not firmly secured to a surface; it was hanging from a concrete form beam by a piece of twine exposing employees to a 110 Volt electrical shock hazard.
Recent events (3)
  • — F (S) $0
  • — C (S) $13260
  • — Z (S) $13260

1926.405 A02 II I

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Dec 11, 2019
Penalty
Initial $10,419 · Current $0 Reduced
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage:  (a) On or about October 17, 2019, a black Southwire SEOW electrical cord located near the base of the tower crane was damaged, exposing employees to a 208 Volt electrical shock hazard.
Recent events (3)
  • — F (S) $0
  • — C (S) $10419
  • — Z (S) $10419

View Facility Solutions Group's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344388319.