Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RAY'S TIRE AND SERVICE CENTER, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of RAY'S TIRE AND SERVICE CENTER, INC. in 2330 DOBBS RD., SAINT AUGUSTINE, FL 32086 (NAICS 441310). OSHA activity number 344389515.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ray'S Tire and Service Center, INC. — free Get an email when a new federal OSHA severe-injury report for Ray'S Tire and Service Center, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2330 DOBBS RD.
City
SAINT AUGUSTINE
State
FL
ZIP
32086
Mailing
1375 U. S. 1, SOUTH, SAINT AUGUSTINE, FL 32084
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
441310
Employees
13
Ownership type
B

7 citations on file for this inspection.

1910.134 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 11, 2020
Abate by
Apr 6, 2020
Penalty
Initial $4,508 · Current $2,705 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  a.    On or about October 18, 2019, in the body shop and spray paint booth, the employer had not developed a respiratory protection program for two painting employees who were required to wear tight-fitting respirators while pouring, mixing, and spraying paints, hardening agents, reducers, sealers, and solvents that contained chemicals including, but not limited to: xylene, ethylbenzene, butanone, toluene, methanol, acetone, heptane, naphtha, methylcyclohexane, hexamethylene diisocyanate, and butyl acetate.
Recent events (2)
  • — I (S) $2704.8
  • — Z (S) $4508

1910.151 C

Serious Gravity 5 1 instance 8 exposed
Issued
Mar 11, 2020
Abate by
Apr 6, 2020
Penalty
Initial $4,508 · Current $2,705 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  a.    On or about October 18, 2019, on the back wall between repair bay 3 and repair bay 4, the eyewash station available for employees who handle corrosive chemicals had not been serviced and was unsanitary.  b.    On or about October 18, 2019, on the back wall at repair bay 2, the eyewash station available to employees who handle corrosive chemicals had not been serviced and was unsanitary.
Recent events (2)
  • — I (S) $2704.8
  • — Z (S) $4508

1910.215 A04

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 11, 2020
Abate by
Apr 6, 2020
Penalty
Initial $4,508 · Current $2,705 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  a.    On or about October 18, 2019, between repair bay 5 and repair bay 6, the right grinding wheel's tool rest on the Dewalt D758 Bench Grinder was adjusted to greater than 1/8-inch from the grinding wheel surface.  b.    On or about October 18, 2019, between repair bay 5 and repair bay 6, the Dewalt D758 Bench Grinder had no tool rest installed for the left grinding wheel.
Recent events (2)
  • — I (S) $2704.8
  • — Z (S) $4508

1910.243 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 11, 2020
Penalty
Initial $9,282 · Current $5,569 Reduced
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4)(a):    a.    On or about October 18, 2019, an employee operating an unguarded Dewalt 4 1/2-inch DWE small angle grinder to cut off a vehicle muffler pipe was exposed to laceration and puncture wound injuries from the cut-off blade.
Recent events (2)
  • — I (S) $5569.2
  • — Z (S) $9282

1910.303 B01

Serious Gravity 10 1 instance 12 exposed
Issued
Mar 11, 2020
Penalty
Initial $9,282 · Current $5,569 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  a.    On or about October 18, 2019, in repair bay 6, the 115-Volt power cord for the fixed wall fan motor had broken insulation at the plug with bare conductors, exposing employees to an electric shock hazard.  b.    On or about October 18, 2019, in repair bay 6, the 220-Volt power cord for the vehicle lift had broken insulation at the plug, exposing employees to an electric shock hazard.  c.    On or about October 18, 2019, in repair bay 2, the 220-Volt plug had been altered in a method not approved by the manufacturer to wire a second power cord from one plug to power both automotive lifts from a single outlet receptacle, exposing employees to a fire and shock hazard.  d.    On or about October 18, 2019, in repair bay 1, a 115-Volt portable trouble light was plugged in without a bulb in the socket, exposing employees to an electric shock hazard from the empty socket.  e.    On or about October 18, 2019, in repair bay 1, on the wall, the 4-receptacle 115-Volt outlet box had arcing damage to one of the 4 receptacles, exposing employees to fire or electric shock hazards.  f.    On or about October 18, 2019, in repair bay 1, a 115-Volt portable trouble light that was used as an extension cord to power the clock had an open light bulb socket, exposing employees to an electric shock hazard.
Recent events (2)
  • — I (S) $5569.2
  • — Z (S) $9282

1910.305 B02 I

Serious Gravity 10 1 instance 9 exposed
Issued
Mar 11, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:(a) (LOCATION) (IDENTIFY EQUIPMENT AND CONDITION(S)) (STATE HAZARD(S) TO EMPLOYEE(S))  a.    On or about October 18, 2019, in repair bay 1, the wiring in the distribution box was not provided with an approved cover, exposing employees to 115-volt shock hazards.  b.    On or about October 18, 2019, in the alcove next to repair bay 1, the junction box was not covered, exposing employees to 115-Volt shock hazards.  c.    On or about October 18, 2019, at the mezzanine staircase, the junction box was not covered, exposing employees to a 115-V electric shock hazard.  d.    On or about October 18, 2019, on the mezzanine, the 4-receptacle outlet box was missing a gland on the cable exiting the upper punch-out hole, exposing employees to a 115-Volt electric shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F02

Other-than-serious 2 instances 9 exposed
Issued
Mar 11, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  a.    On or about October 18, 2019, in repair bay 1, the electrical breaker box was not marked to indicate the purpose of all circuit breaker switches.  b.    On or about October 18, 2019, in repair bay 3, the electrical breaker box was not marked to indicate the purpose of all circuit breaker switches
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344389515.