Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: TERRA UNDERGROUND, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TERRA UNDERGROUND, LLC in EARLY DAWN AVE AND BOGIE DRIVE, POST FALLS, ID 83854 (NAICS 238910). OSHA activity number 344390232.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Terra Underground, LLC for free Get an email when a new federal OSHA severe-injury report for Terra Underground, LLC is published. One employer, no account, unsubscribe in one click.
Site address
EARLY DAWN AVE AND BOGIE DRIVE
City
POST FALLS
State
ID
ZIP
83854
Mailing
PO BOX 2316, HAYDEN, ID 83835
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
2
Ownership type
Private (A)

4 citations on file for this inspection.

1926.28 A

Other-than-serious 1 instance 2 exposed
Issued
Nov 15, 2019
Penalty
Initial $5,304 · Current $0 Reduced
29 CFR 1926.28(a): Appropriate personal protective equipment was not worn by employee(s) in all operations where there was exposure to hazardous conditions:    a) On October 17, 2019 employees were exposed to a struck-by hazard from construction vehicle and heavy equipment traffic.  Employees were not wearing any high visibility clothing or vest.  The employees was not readily visible to the heavy equipment operators and construction vehicle traffic while standing outside of a trench, and while walking around a very active part of the jobsite.  The construction equipment and traffic included, but was not limited to excavators, front end loaders and dump trucks.       Note) Certification of corrective action is required for this item.
Recent events (2)
  • · I (O) $0
  • · Z (S) $5304

1926.651 C02

Other-than-serious 1 instance 2 exposed
Issued
Nov 15, 2019
Abate by
Nov 21, 2019
Penalty
Initial $3,978 · Current $3,978
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:    a) Jobsite: On October 17, 2019 a safe means of egress was not in place while employees worked in two (2) adjacent excavations that were 5.5 to 7 feet deep.             Note) Certification of corrective actions are required for this item.
Recent events (2)
  • · I (O) $3978
  • · Z (S) $3978

1926.651 K02

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 15, 2019
Abate by
Nov 21, 2019
Penalty
Initial $5,304 · Current $4,000 Reduced
29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in a possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees were not removed from the hazardous area until the necessary precautions had been taken to ensure their safety:    a) Jobsite: On October 17, 2019, the competent person on site had visually determined the soil type (type C) and that a protective system (trench box) was needed.  The competent person and another employee proceeded with work activities in two (2) adjacent excavations before a protective system could be put in place.  The excavation depths varied from 5.5 to 7 feet.      Note) Certification of corrective action is required for this item.
Recent events (2)
  • · I (S) $4000
  • · Z (S) $5304

1926.652 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 15, 2019
Abate by
Nov 21, 2019
Penalty
Initial $0 · Current $0
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c) of this section:   a) Jobsite: On October 17, 2019 employees worked in two (2) adjacent excavations pulling tracer wire and otherwise prepping for a new pipe installation.  The excavations measured between 5.5 to 7 feet deep with type C soil.  There were no cave-in protective systems in place.       NOTE) Abatement certification is required for this item.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 344390232.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.