AMMON, ID —
OSHA Inspection: DAVID GARNER CONSTRUCTION LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DAVID GARNER CONSTRUCTION LLC in 4397 BOONER ST., AMMON, ID 83401 (NAICS 238130). OSHA activity number 344393020.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DAVID GARNER CONSTRUCTION LLC
- Site address
- 4397 BOONER ST.
- City
- AMMON
- State
- ID
- ZIP
- 83401
- Mailing
- PO BOX 247, HYDE PARK, UT 84318
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 7
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Nov 7, 2019
- Abate by
- Dec 5, 2019
- Penalty
- Initial $2,842 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (b) 4397 Booner St.: On or about October 17, 2019 and at times prior, at approximately 10.5 feet employees were installing trusses of a single family home without the use of fall protection. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $1500
- — Z (S) $2842
1926.503 A01
- Issued
- Nov 7, 2019
- Abate by
- Dec 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: (a) 4397 Booner St.: On or about October 17, 2019 and at times prior, at approximately 10.5 feet employees were installing trusses of a single family home without the use of fall protection. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at David Garner Construction LLC
View David Garner Construction LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344393020.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.