BEALE AFB, CA —
OSHA Inspection: KEITH BROWN DRYWALL INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of KEITH BROWN DRYWALL INC. in BLDG. 24-25 B WELCOME CENTER, BEALE AFB, CA 95903 (NAICS 238310). OSHA activity number 344393285.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KEITH BROWN DRYWALL INC.
- Site address
- BLDG. 24-25 B WELCOME CENTER
- City
- BEALE AFB
- State
- CA
- ZIP
- 95903
- Mailing
- 2090 OAKLEY LANE, WHEATLAND, CA 95692
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 40
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B02 II
- Issued
- Nov 5, 2019
- Penalty
- Initial $4,790 · Current $3,353 Reduced
General-duty citation text
29 CFR 1926.451(b)(2)(ii): Where scaffolds must be used in areas that the employer can demonstrate are so narrow that platforms and walkways cannot be at least 18 inches (46 cm) wide, employees on those platforms and walkways were not protected from fall: Beal AFB, Welcome Center Project: An employee was conducting drywall work on a 9 inch platform elevated approximately 12 feet 6 inches above ground level and was not provided with fall protection. The employee was exposed to fall hazards.
Recent events (2)
- — I (S) $3353
- — Z (S) $4790
1926.1053 B04
- Issued
- Nov 5, 2019
- Penalty
- Initial $2,874 · Current $2,012 Reduced
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purpose for which they were designed: Beal AFB, Welcome Center Project: An extension ladder's rung was being used to support one side of an elevated platform approximately 12 feet 6 inches above the ground (lower level). The employee was exposed to the fall hazards.
Recent events (2)
- — I (S) $2011.8
- — Z (S) $2874
1926.451 E01
- Issued
- Nov 5, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): Where scaffold platforms were more than 2 feet above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers, stairway-type ladders, ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used for access: Beal AFB, Welcome Center Project: An employee accessed 6 foot 7 inch high work platform installed on a tubular welded frame scaffold by climbing up and descending down through the scaffold frame and cross braces in lieu of using a ladder.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Keith Brown Drywall INC.