BUXTON, ME ·
OSHA Inspection: STRAIGHT UP ROOFING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of STRAIGHT UP ROOFING, LLC in 185 PORTLAND ROAD, BUXTON, ME 04093 (NAICS 238160). OSHA activity number 344395942.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STRAIGHT UP ROOFING, LLC
- Site address
- 185 PORTLAND ROAD
- City
- BUXTON
- State
- ME
- ZIP
- 04093
- Mailing
- 8 RYSHAE DRIVE, GORHAM, ME 04038
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.451 G01 VII
- Issued
- Nov 5, 2019
- Abate by
- Nov 12, 2019
- Penalty
- Initial $3,978 · Current $3,978
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: Job Site - Employees working from roof bracket scaffolding were not protected from falling from heights of up to 45'.
Recent events (1)
- · Z (S) $3978
1926.1053 B01
- Issued
- Nov 5, 2019
- Abate by
- Nov 12, 2019
- Penalty
- Initial $2,842 · Current $2,842
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: Job Site - The two ladders used to gain access to the roof bracket scaffolding did not extend three feet above the scaffold's platforms.