On , OSHA opened a referral safety inspection of TRELLEBORG COATED SYSTEMS US, INC. in 152 BETHANY RD, MONSON, MA 01057 (NAICS 313320). OSHA activity number 344400643.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Trelleborg Coated Systems US, INC. — free Get an email when a new federal OSHA severe-injury report for Trelleborg Coated Systems US, INC. is published. One employer, no account, unsubscribe in one click.
Site address
152 BETHANY RD
City
MONSON
State
MA
ZIP
01057
Mailing
152 BETHANY RD, MONSON, MA 01057
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
313320
Employees
75
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 10 1 instance 7 exposed
Issued
Dec 18, 2019
Abate by
Feb 6, 2020
Penalty
Initial $9,282 · Current $9,282
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.  152 Bethany Rd, Monson, MA: On October 24, 2019 and at times prior, the location of the pneumatic source of energy listed on the TMI machine #2 energy control procedure was not accurate, did not specify types of isolating/lockout devices, and was not able to be located by an authorized employee.
Recent events (1)
  • — Z (S) $9282

1910.147 C06 I

Serious Gravity 5 1 instance 7 exposed
Issued
Dec 18, 2019
Abate by
Feb 6, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  152 Bethany Rd, Monson, MA: As of October 24, 2019, the employer had not performed an annual periodic inspection that ensured each procedure was inspected for inaccuracies during an actual energy control task.  The employer also did not ensure that the inspector reviewed each authorized employee's responsibilities under each energy control procedure.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 18, 2019
Abate by
Feb 6, 2020
Penalty
Initial $9,282 · Current $9,282
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  152 Bethany Rd, Monson, MA: On October 23, 2019 and at times prior, employees who operated the TMI machine #2 in the reverse mode were exposed to the unguarded nip point between the fabric and the rotating roll receiving the fabric.   On October 23, 2019, an employee operating that machine received hand and arm injuries in that unguarded nip point.