NEWARK, NJ —
OSHA Inspection: NEW ROC CONSTRUCTION CORP
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NEW ROC CONSTRUCTION CORP in 515 ELIZABETH AVE, NEWARK, NJ 07112 (NAICS 238140). OSHA activity number 344414016.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NEW ROC CONSTRUCTION CORP
- Site address
- 515 ELIZABETH AVE
- City
- NEWARK
- State
- NJ
- ZIP
- 07112
- Mailing
- 68-60 AUSTIN ST, FOREST HILLS, NY 11375
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 10
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.405 G02 IV
- Issued
- Feb 25, 2020
- Penalty
- Initial $2,313 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Strain relief. Flexible cords were not connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws. Location: 514 Elizabeth Ave., Newark, NJ. a) Employer did not ensure that the electrical cord used by employees to power the Bosch Hammer drill saw was provided with strain relief; on or about 10/28/19.
Recent events (2)
- — I (S) $2000
- — Z (S) $2313
1926.451 D03 VIII
- Issued
- Feb 25, 2020
- Penalty
- Initial $4,048 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.451(d)(3)(viii): Outrigger beams were not placed perpendicular to its bearing support (usually the face of the building or structure). However, where the employer can demonstrate that it is not possible to place an outrigger beam perpendicular to the face of the building or structure because of obstructions that cannot be moved, the outrigger beam may be placed at some other angle, provided opposing angle tiebacks are used. Location: 515 Elizabeth Ave., Newark, NJ. a) Employer did not provide opposing angle tiebacks for outrigger beams that were installed at an angle with respect to the face of the building; on or about 10/28/19.
Recent events (2)
- — I (S) $2000
- — Z (S) $4048
1926.451 D03 X
- Issued
- Feb 25, 2020
- Penalty
- Initial $4,048 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.451(d)(3)(x): Tiebacks were not installed perpendicular to the face of the building or structure, or opposing angle tiebacks were not installed. Tiebacks installed at an angle are prohibited. Location: 515 Elizabeth Ave., Newark, NJ. a) Employer did not installed the tie-backs perpendicular to the building; on or about 10/28/19.
Recent events (2)
- — I (S) $2000
- — Z (S) $4048
1926.451 G01
- Issued
- Feb 25, 2020
- Penalty
- Initial $4,048 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level. Location: Location: 515 Elizabeth Ave., Newark, NJ. a) An employee used a two point suspended scaffold but did not tie off the lanyard to the life line. The employee was exposed to a potential fall hazard of approximately 40 ft. to the floor below; on or about 10/28/19. b) An employee walked/worked from a bridge scaffold that was missing the parapet wall at the access point. The employee was exposed to a potential fall hazard of approximately 15 ft. to the floor below; on or about 10/28/19.
Recent events (2)
- — I (S) $2000
- — Z (S) $4048
1926.1053 B01
- Issued
- Feb 25, 2020
- Penalty
- Initial $2,892 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails should extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access. Location: 515 Elizabeth Ave., Newark, NJ. a) Employer did not ensure that the ladder's side rails used for access to the bridge scaffold were 3 ft. above the working surface; on or about 10/28/19.
Recent events (2)
- — I (S) $2000
- — Z (S) $2892
More inspections at NEW ROC Construction Corp
View NEW ROC Construction Corp's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344414016.