SALEM, OH —
OSHA Inspection: KDC MANAGEMENT, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of KDC MANAGEMENT, INC. in 15292 SALEM-ALLIANCE ROAD, SUITE 1, SALEM, OH 44460 (NAICS 531312). OSHA activity number 344415500.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KDC MANAGEMENT, INC.
- Site address
- 15292 SALEM-ALLIANCE ROAD, SUITE 1
- City
- SALEM
- State
- OH
- ZIP
- 44460
- Mailing
- 6515 LORETTA STREET, HARTVILLE, OH 44632
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 531312
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.213 C01
- Issued
- Dec 10, 2019
- Abate by
- Jan 31, 2020
- Penalty
- Initial $3,978 · Current $2,784 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be positive, reliable, and in true alignment with the saw; and the mounting shall be adequate in strength to resist any reasonable side thrust or other force tending to throw it out of line. On or about October 22, 2019, the employer did not ensure the blade of a Bosch, Model 4100 table saw was guarded with a hood that completely enclosed the portion of the blade above the table.
Recent events (2)
- — I (S) $2784
- — Z (S) $3978
1910.213 C02
- Issued
- Dec 10, 2019
- Abate by
- Jan 31, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(2): Each hand-fed circular ripsaw shall be furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator. The spreader shall be made of hard tempered steel, or its equivalent, and shall be thinner than the saw kerf. It shall be of sufficient width to provide adequate stiffness or rigidity to resist any reasonable side thrust or blow tending to bend or throw it out of position. The spreader shall be attached so that it will remain in true alignment with the saw even when either the saw or table is tilted. The provision of a spreader in connection with grooving, dadoing, or rabbeting is not required. On the completion of such operations, the spreader shall be immediately replaced. On or about October 22, 2019, the employer did not ensure a Bosch, Model 4100 table saw was furnished with spreader device to prevent material from squeezing the saw or being thrown back at the operator.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 C03
- Issued
- Dec 10, 2019
- Abate by
- Jan 31, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(3): Each hand-fed circular ripsaw shall be provided with nonkickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator. They shall be designed to provide adequate holding power for all the thicknesses of materials being cut. On or about October 22, 2019, the employer did not ensure a Bosch, Model 4100 table saw was furnished with nonkickback fingers or dogs.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at KDC Management, INC.
View KDC Management, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 531312)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344415500.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.