OSHA Inspection: HINOSTROZA CABINET SHOP, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HINOSTROZA CABINET SHOP, INC. in 1802 N. RAUL LONGORIA ROAD, SAN JUAN, TX 78589 (NAICS 321999). OSHA activity number 344415534.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hinostroza Cabinet Shop, INC. — free Get an email when a new federal OSHA severe-injury report for Hinostroza Cabinet Shop, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1802 N. RAUL LONGORIA ROAD
City
SAN JUAN
State
TX
ZIP
78589
Mailing
P.O. BOX 51, SAN JUAN, TX 78589
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321999
Employees
10
Ownership type
A

11 citations on file for this inspection.

1910.22 A02

Serious Gravity 10 1 instance 10 exposed
Issued
Apr 22, 2020
Penalty
Initial $4,048 · Current $4,048
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:  On October 30, 2019, and times prior thereto, throughout the production floor areas the employer did not ensure that the work areas were kept free of escaping combustible dust.
Recent events (1)
  • — Z (S) $4048

1910.212 A01

Serious Gravity 5 1 instance 9 exposed
Issued
Apr 22, 2020
Penalty
Initial $2,313 · Current $2,313
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazards:  On October 30, 2019 and times prior there to, at the production floor area, unguarded pneumatic nail guns were provided to employees to conduct nailing operation tasks.
Recent events (1)
  • — Z (S) $2313

1910.213 D01

Serious Gravity 5 1 instance 9 exposed
Issued
Apr 22, 2020
Penalty
Initial $2,892 · Current $2,892
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  On October 30, 2019 and times prior there to, at this cabinet manufacturing facility, employees conducted wood cutting tasks on crosscut table saws without guards.
Recent events (1)
  • — Z (S) $2892

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 22, 2020
Penalty
Initial $2,892 · Current $2,892
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  On October 30, 2019, and times prior there to, an employee conducted unclogging water main tasks, adjacent to an air compressor with an unguarded pulley.
Recent events (1)
  • — Z (S) $2892

1910.219 E01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 22, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o):  On October 30, 2019, and times prior there to, an employee conducted unclogging water main tasks, adjacent to an air compressor with an unguarded horizontal belt.
Recent events (1)
  • — Z (S) $0

1910.242 B

Serious Gravity 5 1 instance 9 exposed
Issued
Apr 22, 2020
Penalty
Initial $2,892 · Current $2,892
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  On October 30, 2020, and times prior there to, at the production floor area, employer allowed the use of compressed air at greater than 30 P.S.I. for cleaning purposes without PPE and chip guarding protection.
Recent events (1)
  • — Z (S) $2892

1910.303 G02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 22, 2020
Penalty
Initial $4,048 · Current $4,048
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of:  On October 30, 2019 and times prior there to, air compressor area, an employee conducts daily tasks where live parts of electric equipment were not guarded against accidental contact, the electrical cabinet was missing the cover.
Recent events (1)
  • — Z (S) $4048

1910.303 F02

Serious Gravity 5 1 instance 10 exposed
Issued
Apr 22, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  On October 30, 2019 and times prior thereto, branch circuit electrical panels, at entrance of the production floor, the disconnecting means to all electrical machines and equipment to energize for use by employees, were not marked to indicate its purpose.
Recent events (1)
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 9 exposed
Issued
Apr 22, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  On October 30, 2019 and times prior thereto, throughout the production floor work area, employees used energized, electrical junction box fittings, without strain relief.
Recent events (1)
  • — Z (S) $0

1910.307 C01

Serious Gravity 10 1 instance 10 exposed
Issued
Apr 22, 2020
Penalty
Initial $4,048 · Current $4,048
29 CFR 1910.307(c)(1): Equipment and associated wiring was not approved as intrinsically safe as permitted in any hazardous location for which it is approved:  On October 30, 2019, and times prior there to, throughout the work site building facility, equipment and associated wiring was not approved for use in class II locations where combustible dust was present.
Recent events (1)
  • — Z (S) $4048

1910.307 B

Serious Gravity 1 1 instance 10 exposed
Issued
Apr 22, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.307(b): Areas designated as hazardous (classified) locations under the Class and Zone system and areas designated under the Class and Division system established after August 13, 2007 were not properly documented:  Throughout the worksite facility, employees conducted wood work activity where wood dust was more than two feet in depth, the employer did not document the area as class II, division I.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344415534.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.