CEDAR CREEK, TX —
OSHA Inspection: AGILENT TECHNOLOGIES INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AGILENT TECHNOLOGIES INC. in 1834 TX-HWY 71 W., CEDAR CREEK, TX 78612 (NAICS 334515). OSHA activity number 344415864.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AGILENT TECHNOLOGIES INC.
- Site address
- 1834 TX-HWY 71 W.
- City
- CEDAR CREEK
- State
- TX
- ZIP
- 78612
- Mailing
- 1834 TX-71, CEDAR CREEK, TX 78612
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334515
- Employees
- 5500
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C06 I
- Issued
- Nov 4, 2019
- Abate by
- Nov 22, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: For the bulk fill tank: On or about October 30, 2019, and at times prior thereto, the employer did not conduct a periodic inspection of the energy control procedures, exposing employees to unexpected start up or release of stored energy of equipment.
Recent events (1)
- — Z (O) $0
1910.305 G02 III
- Issued
- Nov 4, 2019
- Abate by
- Nov 8, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: On or about October 30, 2019, the end of the cord connected to the fermenter machine was not equipped with strain relief and the insulated wires were exposed, exposing the employee to an electrical shock hazard.
Recent events (1)
- — Z (O) $0
More inspections at Agilent Technologies INC.
View Agilent Technologies INC.'s full OSHA safety record →
More inspections in this industry (NAICS 334515)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344415864.