Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MB FOODS LLC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MB FOODS LLC. in 15 N 12 WEST, REXBURG, ID 83440 (NAICS 722513). OSHA activity number 344421987.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MB Foods LLC. — free Get an email when a new federal OSHA severe-injury report for MB Foods LLC. is published. One employer, no account, unsubscribe in one click.
Establishment
MB FOODS LLC.
Site address
15 N 12 WEST
City
REXBURG
State
ID
ZIP
83440
Mailing
1074 BARNEY DAIRY, REXBURG, ID 83440
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722513
Employees
12
Ownership type
A

10 citations on file for this inspection.

1910.110 D10

Serious Gravity 5 1 instance 9 exposed
Issued
Jan 31, 2020
Abate by
Feb 27, 2020
Penalty
Initial $3,084 · Current $1,600 Reduced
29 CFR 1910.110(d)(10): Precautions were not taken to prevent damage to LP gas system(s) from vehicular traffic:    (a)  On or about October 30, 2019, and at times prior thereto, the propane tank was installed where automobile traffic can be expected and/or is present and was not protected from potential impact.     Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $1600
  • — Z (S) $3084

1910.132 D02

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 31, 2020
Abate by
Feb 27, 2020
Penalty
Initial $3,856 · Current $2,000 Reduced
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment had been performed through a written certification that identified the workplace evaluated; the person which certified that the evaluation had been performed; the date(s) of the hazard assessment; and, which identified the document as a certification of hazard assessment.    (a)  On or about October 30, 2019, the employer did not assess the workplace to determine if hazards are present and/or are likely to be present when manually lighting the propane smoker and exposing employees to burn hazards.    Note: Abatement certification and documentation ARE required for this item.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3856

1910.157 E02

Serious Gravity 5 1 instance 9 exposed
Issued
Jan 31, 2020
Abate by
Feb 27, 2020
Penalty
Initial $3,856 · Current $2,000 Reduced
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:    (a):  Back of the building:  On or about October 30, 2019, and at times prior thereto, the fire extinguisher located between the freezer and the smoker.    Note: Abatement certification and documentation ARE required this item .
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3856

1910.157 E03

Serious Gravity 5 1 instance 9 exposed
Issued
Jan 31, 2020
Abate by
Feb 27, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  (a)  Back of the building next to the smoker:  On or about October 30, 2019, and at times prior thereto, the fire extinguisher was not subject to an annual maintenance inspection.  Note: Abatement certification and documentation ARE required this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C04

Serious Gravity 5 1 instance 9 exposed
Issued
Jan 31, 2020
Abate by
Feb 27, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition.  (a)  Back of the building:  On or about October 30, 2019, and at times prior thereto, the fire extinguisher gauge was in the red and in need of maintenance.   Note: Abatement certification and documentation ARE required this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 G01

Serious Gravity 5 1 instance 9 exposed
Issued
Jan 31, 2020
Abate by
Jun 30, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:   (a)     On or about October 30, 2019, and at times prior thereto, the employer permitted employees to use portable fire extinguishers and did not provide training on fire extinguisher use and/or incipient stage fire fighting.  Note:  Abatement certification and documentation ARE required this item.
Recent events (3)
  • — P (S) $0
  • — I (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 2 instances 9 exposed
Issued
Jan 31, 2020
Abate by
Feb 27, 2020
Penalty
Initial $2,313 · Current $1,200 Reduced
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing and labeling.    (a)  On or about October 30, 2019, and at times prior thereto,  the employer had a Commercial Grill and Smoker connected to a Relocatable Power Strip.     (b)  On or about October 30, 2019, and at times prior thereto, the employer had a Commercial Freezer connected to a Relocatable Power Strip.    Note: Abatement certification and documentation ARE required for this item.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2313

1910.305 G01 IV B

Serious Gravity 1 1 instance 9 exposed
Issued
Jan 31, 2020
Abate by
Feb 27, 2020
Penalty
Initial $2,313 · Current $1,200 Reduced
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were used where run through holes in walls, ceilings, or floors:    (a)  On or about October 30, 2019, and at times prior thereto, the employer used flexible wiring to substitute for fixed wiring and had it attached and running through holes in the walls.    NOTE:  Abatement certification IS required for this item
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2313

1910.305 G02 III

Serious Gravity 1 1 instance 9 exposed
Issued
Jan 31, 2020
Abate by
Feb 27, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to the joints or terminal screws:  (a)   On or about October 30, 2019, and at times prior thereto, the male side of an electrical cord lacked strain relief and plugged into a relocatable power tap.  Note: Abatement certification IS required this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 II

Serious Gravity 1 1 instance 9 exposed
Issued
Jan 31, 2020
Abate by
Feb 27, 2020
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used in continuous lengths without splice or tap:  (a)  On or about October 30, 2019, and at times prior thereto, the power cord for the commercial smoker and Sawtooth Pellet Grill had the power cords spliced and/or repaired and taped together.  Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344421987.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.