STEELTON, PA —
OSHA Inspection: ARCELORMITTAL USA INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ARCELORMITTAL USA INC in 215 SOUTH FRONT STREET, STEELTON, PA 17113 (NAICS 331513). OSHA activity number 344436027.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARCELORMITTAL USA INC
- Site address
- 215 SOUTH FRONT STREET
- City
- STEELTON
- State
- PA
- ZIP
- 17113
- Mailing
- 215 SOUTH FRONT STREET, STEELTON, PA 17113
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331513
- Employees
- 325
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.179 L03 I
- Issued
- May 4, 2020
- Abate by
- Jun 30, 2020
- Penalty
- Initial $67,500 · Current $47,250 Reduced
General-duty citation text
29 CFR 1910.179(l)(3)(i): Unsafe condition(s) disclosed during the frequent or periodic inspection(s) required by 29 CFR 1910.179(j) were not corrected before operation of the crane(s) was resumed: a) Steelmaking Building: On or about January 28, 2020, unsafe conditions disclosed in the inspection requirements of 29 CFR 1910.179(j) were not corrected as required and/or adjustments made by designated personnel on the "27 Down-River Pit Crane". Multiple conditions rated as Category E requiring immediate shutdown and Category 1 requiring repair in a month were reported to the employer on a January 19, 2019 and have not been corrected and carried over to a January 28, 2020 report to the employer. b) Steelmaking Building: On or about January 28, 2020, unsafe conditions disclosed in the inspection requirements of 29 CFR 1910.179(j) were not corrected as required and/or adjustments made by designated personnel on the "92 Up-River Charging Crane". Multiple conditions rated as Category E requiring immediate shutdown and Category 1 requiring repair in a month were reported to the employer on a November 26, 2018 and have not been corrected and carried over to a October 23, 2019 report to the employer. c) Steelmaking Building: On or about January 28, 2020, unsafe conditions disclosed in the inspection requirements of 29 CFR 1910.179(j) were not corrected as required and/or adjustments made by designated personnel on the "28 Up-River Pit Crane". Multiple conditions rated as Category 1 requiring repair in a month were reported to the employer in the previous year and have not been corrected and carried over to a January 27, 2020 report to the employer. d) Castor Building: On or about January 28, 2020, unsafe conditions disclosed in the inspection requirements of 29 CFR 1910.179(j) were not corrected as required and/or adjustments made by designated personnel on the "170 Hot Metal Crane". Multiple conditions rated as Category E requiring immediate shutdown and Category 1 requiring repair in a month were reported to the employer on a November 26, 2018 and have not been corrected and carried over to a October 23, 2019 report to the employer. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $47250
- — Z (W) $67500
1910.179 J03
- Issued
- May 4, 2020
- Abate by
- Jun 19, 2020
- Penalty
- Initial $7,210 · Current $0 Reduced
General-duty citation text
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months: a) Steelmaking Building: On or about January 21, 2020, the employer did not perform a periodic inspection that includes all structural components on the "93 Down River Charging Crane" during the past 12 months. The last inspection date for structural components was performed on October 27, 2018. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $7210
More inspections at Arcelormittal USA INC
View Arcelormittal USA INC's full OSHA safety record →
More inspections in this industry (NAICS 331513)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344436027.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.