ATLANTA, GA —
OSHA Inspection: MAIN STEEL POLISHING CO., INC. OF GA
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MAIN STEEL POLISHING CO., INC. OF GA in 761 BEDFORD ST NW, ATLANTA, GA 30318 (NAICS 332813). OSHA activity number 344437702.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAIN STEEL POLISHING CO., INC. OF GA
- Site address
- 761 BEDFORD ST NW
- City
- ATLANTA
- State
- GA
- ZIP
- 30318
- Mailing
- 761 BEDFORD ST NW, ATLANTA, GA 30318
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332813
- Employees
- 17
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Apr 29, 2020
- Penalty
- Initial $12,145 · Current $12,145
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Cut to Length Line - On or about November 5, 2019, the employer exposed employees to caught-in hazards, in that the employer failed to ensure the machine specific lockout procedure for Herr-Voss Precision Leveler was utilized for the control of hazardous energy when authorized employees were cleaning the pinch rolls.
Recent events (1)
- — Z (S) $12145
1910.147 C04 II B
- Issued
- Apr 29, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. a) Cut to Length Line - On or about November 5, 2019, the employer exposed employees to caught-in hazards, in that the employer failed to ensure that the specific lockout/tagout procedure for the Herr-Voss Precision Leveler included how to control and isolate hydraulic energy.
Recent events (1)
- — Z (S) $0
1910.157 C01
- Issued
- Apr 29, 2020
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) Storage area - On or about November 8, 2019, the employer exposed employees to fire hazards in that a portable fire extinguisher was not identified and no sign was provided for the fire extinguisher when employees were working with Herr-Voss Precision Leveler powered by electrical energy.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 332813)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 344437702.